Installation Instructions
Seite/Page 58 - Kaptitel/Chapter 5: Installation Instructions
20.7.15
5.4.3 Installation of the through hull fitting in Yachts - Schema
Fig. 5.4.3-1: Position of the thru hull fitting
It is good practice for yachts to use a through hull fitting
with an integrated strainer. The through hull fitting (raw
water intake) is often mounted against the sailing
direction to induce more water intake for cooling.
For Panda generators, the through hull inlet should NOT point in the
sailing direction! When sailing at higher speeds more water will be
forced into the inlet than the pump can handle and your generator
will flood
.
5.4.4 Quality of the raw water sucking in line
In order to keep the suction resistance in the line at a minimum, the raw water intake system must have an inner
diameter of at least 1" (25 mm).
This applies also to installation components such as through-hull fitting, sea cock, raw water filter etc.
The intake suction line should be kept as short as possible. Install the raw water inlet in close proximity to the
genset.
After start-up the cooling water quantity must be meas-
ured (e.g. by catching at the exhaust). The flow rate, as
well as the necessary cross section of the cooling water
pipe see section 11.10, “Diameter of conduits,” on
page 207
5.4.5 Generator installation above waterline
The Panda is equipped with a water intake pump mounted on the motor. Since the intake pump is an impeller pump
there are wearing parts which are likely to require replacement after a period of time. Ensure that the genset is
installed so that the intake pump can be easily accessed. If this is not possible, an external intake pump could be
installed in an easily accessible location
If the generator is installed above the waterline, it is possible that the impeller will wear out faster, because after
starting, the pump runs dry for some seconds. The raw water hose should form a loop as near as possible to the raw
water inlet of the generator (see picture below). This ensures the pump only sucks in air for a short time. The
impeller pump will be lubricated by raw water and the impeller life span will be increased.With the installation of a
non return valve in the raw water inlet line, which is under the waterline, this problem can be restricted.
When starting the generator you should always consider when raw water runs out of the exhaust system. If this
takes longer than 5 seconds you should replace the impeller pump because it sucks in air for too long before it
delivers raw water. The impeller has lost its effect and cannot suck in raw water anymore. This results to an
overheating of the motor. If the impeller is not exchanged early enough the impeller blades may break into pieces
and plugging the cooling water cycle. It is very important to exchange the impeller after a couple of months.
Содержание Panda 25i PMS
Страница 10: ...Seite Page 10 Kapitel Chapter 1 20 7 15 Leere Seite Intentionally blank...
Страница 146: ...Generator Failure Seite Page 146 Kaptitel Chapter 8 Generator Failure 20 7 15...
Страница 158: ...Tables Seite Page 158 Kaptitel Chapter 9 Tables 20 7 15...
Страница 180: ...Inverter Panda PMGi 25 Seite Page 180 Kaptitel Chapter 10 Inverter Panda PMGi 25 20 7 15...
Страница 208: ...Seite Page 208 Kapitel Chapter 13 Installation 20 7 15 Leere Seite Intentionally blank Installation...
Страница 210: ...Seite Page 210 Kapitel Chapter 14 Maintenance 20 7 15 Leere Seite Intentionally blank Maintenance...
Страница 216: ...Seite Page 216 Kapitel Chapter 16 Annex 20 7 15 Leere Seite Intentionally blank Annex...