General operation
Seite/Page 172 - Kaptitel/Chapter 11: General operation
16.1.15
11.2 Starting preparation / Checks (daily)
11.2.1 Marine version
1. Oil level control (ideal level: 2/3 MAX).
The level should be about 2/3 of the maximum level of a cold engine.
Further, if installed, the oil level of the oil-cooled bearing must be controlled before each start - see sediment bowl
at generator front cover!.
2. State of cooling water.
The external expansion tank should be filled up to 1/3 of the maximum in a cold state. It is very important that a
large expansion area remains above the cooling water level.
3. Check if sea cock for cooling water intake is open.
For safety reasons, the sea cock must be closed after the generator has been switched off. It should be re-
opened before starting the generator.
4. Check raw water filter.
The raw water filter must be regularly checked and cleaned. The impeller fatigue increases, if residual affects the
raw water intake.
5. Visual inspection.
Control fixing bolts, check hose connectors for leakages, control electrical connections.
6. Switch off the load.
The generator should only be started without load.
7. Open fuel valve, if installed.
8. Close battery main switch (on).
11.2.2 Vehicle version
1. Oil level control (ideal level: 2/3 MAX).
The level should be about 2/3 of the maximum level of a cold engine.
Further, if installed, the oil level of the oil-cooled bearing must be controlled before each start - see sediment bowl
at generator front cover!.
2. State of cooling water.
The external expansion tank should be filled up to 1/3 of the maximum in a cold state. It is very important that a
large expansion area remains above the cooling water level.
3. Visual inspection.
Control fixing bolts, check hose connectors for leakages, control electrical connections.
4. Switch off the load.
The generator should only be started without load.
5. Open fuel valve, if installed.
Close battery main switch (on).
Содержание 10000i
Страница 10: ...Seite Page 10 Kapitel Chapter 2 16 1 15 Leere Seite Intentionally blank ...
Страница 146: ...Maintenance Instructions Seite Page 146 Kaptitel Chapter 7 Maintenance Instructions 16 1 15 7 22 ...
Страница 156: ...Generator Failure Seite Page 156 Kaptitel Chapter 8 Generator Failure 16 1 15 ...
Страница 194: ...Seite Page 194 Kapitel Chapter 12 Installation 16 1 15 Leere Seite Intentionally blank Installation ...
Страница 196: ...Seite Page 196 Kapitel Chapter 13 Maintenance 16 1 15 Leere Seite Intentionally blank Maintenance ...
Страница 202: ...Seite Page 202 Kapitel Chapter 15 Annex 16 1 15 Leere Seite Intentionally blank Annex ...