Maintenance Instructions
Seite/Page 122 - Kaptitel/Chapter 7: Maintenance Instructions
16.1.15
This ventilating procedure must be repeated several times:
The generator must be switched off before opening the
ventilating points!
Pay attention that the external coolant expansion tank is
connected with the generator by the intended
connection point.
Further it should be guaranteed that the expansion tank
is attached in sufficient height (600 m) over the level of
the generator exhaust elbow union.
Fig. 7.10-1: Expansion tank
Expansion tank
Fig. 7.10-2: Ventilating screw
1. Open the ventilating screw above the cooling water pump
casing. Not present at all models
Use spanner size 10 mm.
Not present at all models