Maintenance Instructions
16.1.15
Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 119
Fig. 7.9-3: Injection nozzles
4. Pressing the starter button can now start the machine.
The machine should start after a short period.
5. If this does not occur, then a connecting nut fitted to the
injection line must be loosened and starting procedure
repeated. Retighten the washers after successfully
starting. The injection line must be raised by several
millimetres.
Use spanner size 17 mm.
6. Switch main switch „OFF“.
7.9.1 Replacement of the fuel filter
Fig. 7.9.1-1: Fuel Filter
Exchanging the filter, depending upon fuel contamination,
should take place after 300 operational hours at the very
least. The inlet must be clamped, before exchanging the
filter.
Remove the hoses from the used filter and fasten them to the
new filter. The arrow on the filter housing indicates the
direction of the fuel flow. A clogged filter causes a decreased
power output of the generator.
7.9.1.1 Optional fuel filter with sight glass
Fig. 7.9.1.1-1: Fuel filter
The filter change depends on the fuels’ degree of pollution,
but should be executed every 300 operating hours at the
latest.
01. Fuel filter housing
02. Fuel filter element
03. Sight glass
01
02
03
Содержание 10000i
Страница 10: ...Seite Page 10 Kapitel Chapter 2 16 1 15 Leere Seite Intentionally blank ...
Страница 146: ...Maintenance Instructions Seite Page 146 Kaptitel Chapter 7 Maintenance Instructions 16 1 15 7 22 ...
Страница 156: ...Generator Failure Seite Page 156 Kaptitel Chapter 8 Generator Failure 16 1 15 ...
Страница 194: ...Seite Page 194 Kapitel Chapter 12 Installation 16 1 15 Leere Seite Intentionally blank Installation ...
Страница 196: ...Seite Page 196 Kapitel Chapter 13 Maintenance 16 1 15 Leere Seite Intentionally blank Maintenance ...
Страница 202: ...Seite Page 202 Kapitel Chapter 15 Annex 16 1 15 Leere Seite Intentionally blank Annex ...