![Fischer Panda 10000i Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/fischer-panda/10000i/10000i_manual_2294273095.webp)
Installation Instructions
16.1.15
Kapitel/Chapter 5: Installation Instructions - Seite/Page 95
5.16 Technical Data
Characteristics
closed current (electronics off)
0,5mA
closed current (electronics on)
10 - 15mA
Benchmark figure of the temperature control:
fan start-up
60°C - 80°C
max. number of revolution
65°C - 100°C
tolerance of the temperatures
± 5%
Maximum ratings
maximum ambient temperature (for operation)
50°C
Maximum ratings: Battery operation 12V
nominal load operating voltage (continuity)
11 VDC - 14.4 VDC
load operating voltage (15min)
- 16.0 VDC
maximum idle speed operating voltage (3 sec)
17 VDC
nominal load current (continuity)
40 A
maximum load current (3 sec)
44 A
nominal voltage fan
12 VDC
Maximum ratings: Battery operation 24V
nominal load operating voltage (continuity)
18 VDC - 28.0 VDC
load operating voltage (15min)
- 28.8 VDC
maximum load operating voltage (3 sec)
30 VDC
idle speed voltage (continuity)
34 VDC
maximum idle speed operating voltage (3 sec)
36 A
nominal load current (continuity)
20 A
maximum load current (3 sec)
22 A
nominal voltage fan
24 VDC
Maximum ratings: Transformer operation 12V
sieving in the power supply
10000µF 63V (depending on the load current)
data for secondary winding after rectification/sieving
nominal load operating voltage (continuity)
11 VDC - 14.4 VDC
load operating voltage (15min)
- 16.0 VDC
maximum load operating voltage (3 sec)
17 VDC
idle speed operating voltage (continuity)
28 VDC
maximum idle speed operating voltage (3 sec)
30 VDC
nominal load current (continuity)
40 A
maximum load current (3 sec)
44 A
nominal voltage fan
12 VDC
Maximum ratings: Transformer operation 24V
sieving in the power supply
10000µF 63V (depending on the load current)
data for secondary winding after rectification/sieving
full load operating voltage (15min)
18 VDC - 28.0 VDC
load operating voltage (15min)
- 28.8 VDC
maximum full load operating voltage (3 sec)
30.0 VDC
maximum partial load operating voltage
36.0 VDC
idle speed operating voltage (continuity)
39.0 VDC
maximum idle speed operating voltage (3 sec)
40.0 VDC
maximum input peak voltage
44.0 VDC *1)
maximum output peak voltage
44.0 VDC *1)
nominal load current (continuity)
24 A
Содержание 10000i
Страница 10: ...Seite Page 10 Kapitel Chapter 2 16 1 15 Leere Seite Intentionally blank ...
Страница 146: ...Maintenance Instructions Seite Page 146 Kaptitel Chapter 7 Maintenance Instructions 16 1 15 7 22 ...
Страница 156: ...Generator Failure Seite Page 156 Kaptitel Chapter 8 Generator Failure 16 1 15 ...
Страница 194: ...Seite Page 194 Kapitel Chapter 12 Installation 16 1 15 Leere Seite Intentionally blank Installation ...
Страница 196: ...Seite Page 196 Kapitel Chapter 13 Maintenance 16 1 15 Leere Seite Intentionally blank Maintenance ...
Страница 202: ...Seite Page 202 Kapitel Chapter 15 Annex 16 1 15 Leere Seite Intentionally blank Annex ...