Installation Instructions
Seite/Page 96 - Kaptitel/Chapter 5: Installation Instructions
16.1.15
*1) The maximum input and/or output peak voltage is measured over the appropriate
clamps of the fan controller. It may be exceeded at no time. This applies independently
of whether a voltage increased height was possibly caused by the fan controller or an
external component. To this belong the switch off-transient of the fan (pulse width
modulation = fan will be 2000 times per second switched on and off), and by outside
switching operation caused glitches.
Attention!: Configuration at delivery for 24V-
operation.
• solder joint J101 closed
• solder joint J102 open
• main fuse 30A installed
• output fuse 20A installed
For 12V-operation the installed fuses must be replaced
against the provided fuses, as described above. The pre-
resistors for the operating voltage of control electronics
must be configured like above described.
Assembly: Vertical on standard rail, pay attention to good ventilation.
At breach of specification can destroy one or more components of the system or shorten the life span
substantially.
Subject to change without prior notice.
maximum load current (3 sec)
28 A
nominal voltage fan
24 VDC
Содержание 10000i
Страница 10: ...Seite Page 10 Kapitel Chapter 2 16 1 15 Leere Seite Intentionally blank ...
Страница 146: ...Maintenance Instructions Seite Page 146 Kaptitel Chapter 7 Maintenance Instructions 16 1 15 7 22 ...
Страница 156: ...Generator Failure Seite Page 156 Kaptitel Chapter 8 Generator Failure 16 1 15 ...
Страница 194: ...Seite Page 194 Kapitel Chapter 12 Installation 16 1 15 Leere Seite Intentionally blank Installation ...
Страница 196: ...Seite Page 196 Kapitel Chapter 13 Maintenance 16 1 15 Leere Seite Intentionally blank Maintenance ...
Страница 202: ...Seite Page 202 Kapitel Chapter 15 Annex 16 1 15 Leere Seite Intentionally blank Annex ...