Installation Instructions
Seite/Page 76 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 5: Installation Instructions
11.3.11
5.7
Installation of the fuel system
5.7.1 General references
Inside the generator capsule itself, there is the fuel filter installed (exception: Panda 4200 and 4500). Additional fuel
filters (with water separator) must be mounted outside the capsule in easily accessible places in the fuel lines bet-
ween the tank intake fuel pump and the diesel motor's fuel pump.
Generally forward and return fuel flow pipes must be mounted to the diesel tanks. Do not connect the generator fuel
supply lines with any other fuel lines of other diesel systems.
• The following items need to be installed:
• Fuel supply pump (DC)
• Pre-filter with water separator (not part of the delivery)
• Fine particle fuel filter
• Return fuel line to fuel tank (unpressurized)
The fuel supply pump should be mounted as close to the fuel tank as possible. The electric cable for the fuel pump
is already installed on the generator (length 5 m).
Fig. 5.7.1-1: Installation Scheme Fuel System
1
2
3
4
5
8
7
6
1. Generator
2. Fuel stopcock
3. Fuel filter
4. Fuel return
5. Condensation water suction pump (optional)
6. Fuel tank
7. Fuel supply
8. Electrical fuel pump (DC)
Содержание 10000 NE
Страница 26: ...Seite Page 26 General R01 1 11 3 11 Leere Seite Intentionally blank General References and Regulations...
Страница 162: ...Seite Page 162 Panda PMS 8 000 NE 42 NE Manual R05 11 3 11 Leere Seite Intentionally blank Generator Faults...
Страница 208: ...Seite Page 208 Panel Generator Control P6 RE0703_Kunde_eng R06 1 11 3 11 Leere Seite Intentionally blank Measurements...