Maintenance Instructions
Seite/Page 116 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 6: Maintenance Instructions
11.3.11
Fig. 6.10.2-22: Mount the bearing housing
With the other hand, loosely screw in the lifting screws for gui-
dance.
Fig. 6.10.2-23: Mount the bearing housing
Now carefully press the bearing housing in its seat with a soft
headed hammer (or hammer plus mandrel).
By doing that, shift the mandrel after each scale in a circle to avoid canting.
Otherwise you might risk that the housing is a little bit canted because of the
material that is curled up by the lifting screws.
A canted bearing housing causes a canted ball bearing, which will wear out
very quickly!
Fig. 6.10.2-24: Tighten the fastening screws
Tighten the fastening screws M8 with 22 to 25 Nm (Tool: Allen
wrench SW6).
Содержание 10000 NE
Страница 26: ...Seite Page 26 General R01 1 11 3 11 Leere Seite Intentionally blank General References and Regulations...
Страница 162: ...Seite Page 162 Panda PMS 8 000 NE 42 NE Manual R05 11 3 11 Leere Seite Intentionally blank Generator Faults...
Страница 208: ...Seite Page 208 Panel Generator Control P6 RE0703_Kunde_eng R06 1 11 3 11 Leere Seite Intentionally blank Measurements...