General References and Regulations
11.3.11
General.R01.1 - Kapitel/Chapter 1: General References and Regulations Seite/Page 23
1.6.1.4 Safety instructions concerning the cables
Cable Type
It is recommended is that the cable used be UL 1426 (BC-5W2) compliant, with Type 3 stranding (ABYC Section E-
11)
Cable Size
The cable size must be selected taking into account the amperage, voltage and conductor length (from the positive
power source connection to the electrical device and back to the negative power source connection.
Cable Installation
It is recommended that a self draining wire loom classified as V-2 or better in accordance with UL 94 be installed in
the section of the cable routed in the interior of the sound capsule. Care should be taken to avoid hot surfaces such
as the exhaust manifold or engine oil drain bolt and routed clear of any possible sources of chafing.
1.6.2 Recommended starter battery size
Only use batteries which are certified as starter battery by the manufacturer.
Only use batteries with capacity recommended by the engine manufacturer.
1.6.3 Important Advice for Batteries - Starting batteries and Traction batteries
ATTENTION!!! Initial operation:
Installation of battery lines.
Consider the regulations and installation instructions of the battery manufacturer.
Consider ABYC regulation E11 AC and DC electrical systems on boats and/or EN ISO
10133:2000 small watercrafts, electrical systems, low voltage (DC) systems !
Ensure a professional battery installation.
The battery separation can be made mechanically or by an appropriate power relay.
Consider the appropriate notes of the battery manufacturer concerning fire and explosion pre-
vention.
Install a right sized fuse in the positive battery line as close as possible to the battery, but max.
12 inch, 300mm from the battery.
The length of the cable to the fuse, the cable must be protected by a sheath or conduit against damage of the insu-
Attention !! Check before installation if the starter battery voltage correspond with the genera-
tor start system.
f.e. 12V starter battery for 12V start system
f.e. 24V starter battery for 24V start system