Maintenance Instructions
Seite/Page 106 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 6: Maintenance Instructions
11.3.11
6.9
Checking the oil level of the generator end bearing at Fischer Panda
generators
The oil level check is a visual check. Older generators are equipped with an sight glass, newer ones with an sight
hose.
Fig. 6.9-1: Oil check
If your generator does not feature these control modules or if these are not accessable, please refer to your Fischer
Panda distribution partner or to Fischer Panda directly. The correct oil level is at the middle of the sight glass/ sight
hose.
Oil level check is only to be executed when the generator is switched off!
6.9.1 Oil level check
Fig. 6.9-1: Oil level check
01
02
03
Older version
Newer version
01. Screw plug
02. Sight glass
03. Sight hose
Oil level check
Oil level is fine:
Generator can be started.
Next check: after 25 hours
Oil level is NOT correct:
Correct the oil level. Let generator
run for 3 minutes
Oil level is fine:
Generator can be started.
Next check: after 5 hours
Oil level still NOT correct:
Do NOT restart generator!
Oil level is fine:
Generator
can
be
started
Oil level still NOT correct:
Refill oil
Let generator run for 3 minutes
Содержание 10000 NE
Страница 26: ...Seite Page 26 General R01 1 11 3 11 Leere Seite Intentionally blank General References and Regulations...
Страница 162: ...Seite Page 162 Panda PMS 8 000 NE 42 NE Manual R05 11 3 11 Leere Seite Intentionally blank Generator Faults...
Страница 208: ...Seite Page 208 Panel Generator Control P6 RE0703_Kunde_eng R06 1 11 3 11 Leere Seite Intentionally blank Measurements...