Maintenance Instructions
11.3.11
Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 103
Fig. 6.8.1.3-1: 1Mount bearing cover
Mount bearing case in the generator cap.
Place bearing case loosely into the generator cap, assure with
one hand against falling out.
Thereby pay attention that the case is mounted in the same
position as before - the previously added markings have to
match again!
Sample Picture
Fig. 6.8.1.3-2: Bearing case mouting
With the other hand, loosely screw in the ejector screws as
guide line.
Sample Picture
Fig. 6.8.1.3-3: Press fit bearing case
Carefully press the bearing case with a soft-head hammer (or a
hammer plus mandrel) in its hub.
Thereby relocated mandrel rotatory after each hit to avoid can-
ting.
Otherwise there is a risk that the case is slightly canted
because of the material which is brought up by the ejector
screws.
A canted bearing case causes a canted ball bearing, which will
wear out quite fast!
Sample Picture