background image

Connector 4 (CN4), 20-Pin:  Programmable Output Connector (POC)

IMPORTANT: 

 

Odd Pin numbers 1 through 17 are programmable for up to 19 different output types.  

Refer to Special Option Group 2 for complete details.

Pin 1  Blue - 250mA negative (-) output when armed and during remote start (while running). This wire has  
 

a connector and must plug into same wire at the starter-kill relay. Caution:  When this wire is being    

 

used to trigger aftermarket accessories it must be diode isolated. 

Pin 2   Not Used 

Pin 3  Green/White [POC 1] - Parking light 250mA negative (-) output. The proper wire will test (-) when    
 

the parking light switch is in the on position.

Pin 4  Not Used

Pin 5   Red/Black [POC 2] - Auxiliary 5 250mA negative (-) output. This is an optional output that will  

 

 

provide a programmable output to trigger sliding doors, power windows or whatever other features    

 

you’d like.

Pin 6   Light Blue/White - Foot brake (+) input. This is used for option 1-09: Igniton controlled door locks 
 

setting 2 which will let the doors lock when brake is pressed.

Pin 7  Green [POC 3] - Auxiliary 4 250mA negative (-) output. This is an optional output that will provide a  
 

programmable output to trigger sliding doors, power windows or whatever other features you’d like.

Pin 8  Violet/Black - Trunk negative (-) input. This is an optional input that will monitor when the vehicle’s    
 

trunk has been opened. The proper wire will provide a (-) trigger while the trunk is open.

Pin 9  White/Black [POC 4] - Auxiliary 3 250mA negative (-) output. This is an optional output that will  

 

 

provide a programmable output to trigger sliding doors, power windows or whatever other features    

 

you’d like.

Pin 10  Red/White - Door trigger input. This wire monitors negative (-) or positive (+) trigger door-pins. The   
 

proper wire will provide a (-) trigger or a (+) trigger only when the doors are opened. You will  

 

need to test the wire for proper polarity and set door dip switch on the control module for the 

 

corresponding polarity.

Connector 3 (CN3) , 20 Pin Blade Connector - New Generation

This connector is used only if you are installing a Blade-AL or Blade-TB. The wiring harness for this 
connector also comes with the Blade cartridge. Please refer to the Blade install guide for wire description.  
The new generation 20 pin Blade connector now has a locking tab. The old connector with out a locking 
tab is compatible but you must modify the connector.

CM6300

 

Install Guide

Alarm System

www.firstechonline.com | www.compustar.com

Copyright 2012 Firstech, LLC.

Page 15

Содержание CM6300

Страница 1: ...lease visit www firstechonline com for additional installation resources MODEL RF 2W900FM 5PT Firstech LLC 21903 68th Ave S Kent WA 98032 Phone 888 820 3690 Fax 206 957 3330 Installation Manual CM6300...

Страница 2: ...duction 4 Kit Contents 4 Installation Basics 5 Remote Programming Routine 6 Placement and Use of Components 6 Common Procedures 12 Wiring Descriptions 13 Option Programming Tables 20 Option Menu Descr...

Страница 3: ...CM6300 Install Guide Alarm System www firstechonline com www compustar com Copyright 2012 Firstech LLC Page 3...

Страница 4: ...T 6300A CONT controllers include the following CM6300 main control module Wiring diagram sheet Main wiring harness Wiring harnesses Hood pin Mountable bright blue LED Firstech dual stage shock sensor...

Страница 5: ...s as well as the current ones Do not have antennas plugged into both ports on the CM6300 as the remotes will not function properly Supports Blade The CM6300 supports the Blade AL and TB systems as wel...

Страница 6: ...ogramming Multiple Remotes After the confirmation flash given in STEP 2 code additional remotes by tapping Button I on two way remotes or the Lock button on one way remotes The parking lights will fla...

Страница 7: ...gnition to the ON position and leave driver s door open STEP 3 Hold your finger over the Red Circle icon for 2 5 seconds STEP 4 When the siren chirps and LEDs flash in a circular pattern tap on your f...

Страница 8: ...Trunk and Key Start 2W901R SS buttons simultaneously for 2 5 seconds The remote will beep indicating that you have successfully exited programming RPS Remote Paging Sensor Unlock Disarm RPS and car ca...

Страница 9: ...ve times The Secure Valet Switch is more secure than traditional toggle valet switches because it requires a two digit code To program this feature you must perform the following procedures STEP 1 Tur...

Страница 10: ...hrough 10 least sensitive This sets the impact sensitivity of Warn Away Zone 1 Setting Zone 1 will automatically set Zone 2 If you would like to manually set Zone 2 proceed To set Instant Trigger Zone...

Страница 11: ...r the Authorized Tech section document titled FT EZGO Recommended Mounting Locations STEP 7 Program your EZ100 R and additional RF Kit remotes to the control module Maximum 3 Remotes including EZ100 R...

Страница 12: ...ain outputs If these jumpers are used incorrectly damage to the vehicle and or control module may occur Jumper 1 Door Trigger Polarity Determines the polarity of the door trigger input wire red white...

Страница 13: ...www firstechonline com www compustar com Copyright 2012 Firstech LLC Page 13 STEP 4 The control modules have a secure auxiliary option 4 05 This requires you to tap button 4 before you tap button 2 fo...

Страница 14: ...ey in the off position 12V while the key is in the on position and 12V during crank This pin also has a thin green wire that is prewired to the starter kill relay If you are not installing starter kil...

Страница 15: ...output to trigger sliding doors power windows or whatever other features you d like Pin 8 Violet Black Trunk negative input This is an optional input that will monitor when the vehicle s trunk has bee...

Страница 16: ...llow Black Tach Sense input Connect this wire to a tach source for Ignition controlled door locks This is option 1 09 setting 3 The doors will lock once the rpms double from what they are programmed a...

Страница 17: ...for trigger door lock systems For additional lock settings review Option Group 1 Pin 5 Blue Black Lock 250mA negative output This is an optional output that will provide a pulse for locking doors Sys...

Страница 18: ...cables 4 to 4 or 4 to 6 Pin antenna cables do not work Do not use both Connector 9 and Connector 10 at the same time Connector 9 CN9 2 Pin Pre wired Thermister Plug optional thermister into this conn...

Страница 19: ...Black Negative ground Pin 2 White 2nd stage negative input Instant trigger Pin 3 Red 12V positive output Pin 4 Yellow 1st stage negative input Warn away Connector 14 CN14 4 Pin Optional Sensor Input...

Страница 20: ...ure Default Setting I Optional Setting II Optional Setting III Optional Setting IV 1 02 Lock Unlock pulse duration 0 8 sec 2 5 sec 0 125 sec 3 5 sec 1 03 Driver s priority unlock Off On 1 04 Double pu...

Страница 21: ...g Input Key Sense Input Disable Arm Disarm when Brown White Wire Triggered Same Time 4 11 Bypass Through RS232 Port ADS Fortin 4 12 Impact Sensor Shock Sensor DAS Sensor 1st Stage Disarm Input 2nd Sta...

Страница 22: ...again within 4 seconds the other doors will unlock The driver s door unlock must be isolated from the other doors and use the blue unlock The Orange Black CN4 will be used for your 2nd Unlock output t...

Страница 23: ...re changes the behavior of the small orange white disarm wire When the feature is turned on it will change the default single pulse to double pulse upon disarm unlock 1 14 Auto Mode EZ GO This feature...

Страница 24: ...grind circuit while the vehicle is remote started if the anti grind circuit is active and the start kill relay is installed in the ignition the relay will buzz while remote started 3 06 Factory Alarm...

Страница 25: ...ation to be set for a specific length of time 1 99 sec only available when using the OP500 4 03 Aux 1 Output Control This feature allows the user to configure the method of which Auxiliary 1 can be ac...

Страница 26: ...2 4 12 Impact Sensor This feature changes between the standard included shock sensor and the optional DAS Digital Adjustable Sensor The DAS has additional programming Please see the Placement and Use...

Страница 27: ...you will need change special option 5 to number 10 This must be done with the OP500 Option Programming CM6300 Option Programming Using the OP500 programmer The OP500 can be used to program any availa...

Страница 28: ...so read this section in its entirety before beginning IMPORTANT Special Option Groups cannot be programmed with a remote the OP500 must be used STEP 1 Select the option menu that contains the desired...

Страница 29: ...for 2 5 seconds then Lock Key for 2 5 seconds Tap Key Button Tap Lock Button Tap Unlock Button Hold Trunk Button for 2 5 seconds Tap Key Button STEP 2 Scroll through menu allowing for 1 parking light...

Страница 30: ...nds Tap Lock Button Tap Unlock Button Tap Key Button Hold Trunk Key for 2 5 seconds Option Menu 4 Lock Key for 2 5 seconds then Lock Key for 2 5 seconds Hold Trunk Key for 2 5 seconds Tap Lock Button...

Страница 31: ...You no longer need to program the remotes before the OP500 will sync I need a ground when armed wire does the control module have one A You can use the ground when armed wire on CN3 that goes to the...

Страница 32: ...the Ignition on and hold buttons 1 and 4 or Lock and Key Start for 2 5 seconds then the parking lights will flash 1 time on the CM6 series showing V 1 and so forth Current version 3 11 should show 3 f...

Отзывы: