background image

3-02    Confirmation chirps- This feature will allow the user to select a shorter siren output time to simulate    
 

a quieter arm/disarm/start output. 

3-03  Dome Light Delay – This option is used when connecting the door trigger input to the vehicles dome   
 

light circuit.  It delays the door trigger input to prevent the door open icon displaying on 2 Way  

 

 

remotes upon lock/arm. 

3-04  Starter-Kill – This option determines the mode of the anti-grind/starter-kill relay.
 

Default 1: Anti-grind + starter-kill  

 

Option 2: Anti-grind only (no starter-kill)

 

Option 3: Anti-grind + passive starter-kill:  starter-kill activates in 45 seconds after ignition is turned   

 

off.

3-05  Anti-Jacking – This option requires the starter-kill relay to be wired to the ignition vs. the starter wire.
 

Default 1: Acts like starter-kill:  removes power from the ignition, which allows the car to crank but    

 

not start.

 

Option 2: Turns on anti-jacking:  when the remote panics the system, power from the ignition will be   

 

removed at the end of the 30 second siren duration, thereby disabling the vehicle.

 

IMPORTANT:

  When using ignition-kill on manual transmission vehicles Option 2 will need to be    

 

utilized. Option 2 disables the anti-grind circuit while the vehicle is remote-started; if the anti-grind    

 

circuit is active and the start-kill relay is installed in the ignition, the relay will “buzz” while remote-   

 

started. 

3-06   Factory Alarm Option- This feature is default to on, when set to option 2 the security features of the    
 

CM6300 will be deactivated leaving the keyless features functional. 

 
3-07  Siren Duration (Upon Alarm Trigger) - This option changes the time that the siren sounds during  
 

alarm trigger. The available options are 30, 60, and 120 seconds. It will also sound chirps for 20 

 

seconds as a fourth option.

3-08  Horn Output - This feature will change the behavior of horn output (white wire POC8 CN3). 
 
3-09  Siren Output - This Feature will change the behavior of the siren output (brown wire CN3

3-10  Valet – This option changes valet modes.

 

Default 1: Key on/off five times or remote valet (I + III for 0.5 seconds) with key in the on position.

 

Option 2: Key on/off five times or remote valet (I+III for 0.5 seconds) – key does not need to be in    

 

the on position.

 

Option 3: Secure valet: RPS Valet or remote valet (I+III for 0.5 seconds) – this option prevents the    

 

system from being put into valet via key on/off five times. To set up the RPS Valet feature, review the    

 

“Placement and Use of Components” section.

CM6300

 

Install Guide

Alarm System

www.firstechonline.com | www.compustar.com

Copyright 2012 Firstech, LLC.

Page 24

Содержание CM6300

Страница 1: ...lease visit www firstechonline com for additional installation resources MODEL RF 2W900FM 5PT Firstech LLC 21903 68th Ave S Kent WA 98032 Phone 888 820 3690 Fax 206 957 3330 Installation Manual CM6300...

Страница 2: ...duction 4 Kit Contents 4 Installation Basics 5 Remote Programming Routine 6 Placement and Use of Components 6 Common Procedures 12 Wiring Descriptions 13 Option Programming Tables 20 Option Menu Descr...

Страница 3: ...CM6300 Install Guide Alarm System www firstechonline com www compustar com Copyright 2012 Firstech LLC Page 3...

Страница 4: ...T 6300A CONT controllers include the following CM6300 main control module Wiring diagram sheet Main wiring harness Wiring harnesses Hood pin Mountable bright blue LED Firstech dual stage shock sensor...

Страница 5: ...s as well as the current ones Do not have antennas plugged into both ports on the CM6300 as the remotes will not function properly Supports Blade The CM6300 supports the Blade AL and TB systems as wel...

Страница 6: ...ogramming Multiple Remotes After the confirmation flash given in STEP 2 code additional remotes by tapping Button I on two way remotes or the Lock button on one way remotes The parking lights will fla...

Страница 7: ...gnition to the ON position and leave driver s door open STEP 3 Hold your finger over the Red Circle icon for 2 5 seconds STEP 4 When the siren chirps and LEDs flash in a circular pattern tap on your f...

Страница 8: ...Trunk and Key Start 2W901R SS buttons simultaneously for 2 5 seconds The remote will beep indicating that you have successfully exited programming RPS Remote Paging Sensor Unlock Disarm RPS and car ca...

Страница 9: ...ve times The Secure Valet Switch is more secure than traditional toggle valet switches because it requires a two digit code To program this feature you must perform the following procedures STEP 1 Tur...

Страница 10: ...hrough 10 least sensitive This sets the impact sensitivity of Warn Away Zone 1 Setting Zone 1 will automatically set Zone 2 If you would like to manually set Zone 2 proceed To set Instant Trigger Zone...

Страница 11: ...r the Authorized Tech section document titled FT EZGO Recommended Mounting Locations STEP 7 Program your EZ100 R and additional RF Kit remotes to the control module Maximum 3 Remotes including EZ100 R...

Страница 12: ...ain outputs If these jumpers are used incorrectly damage to the vehicle and or control module may occur Jumper 1 Door Trigger Polarity Determines the polarity of the door trigger input wire red white...

Страница 13: ...www firstechonline com www compustar com Copyright 2012 Firstech LLC Page 13 STEP 4 The control modules have a secure auxiliary option 4 05 This requires you to tap button 4 before you tap button 2 fo...

Страница 14: ...ey in the off position 12V while the key is in the on position and 12V during crank This pin also has a thin green wire that is prewired to the starter kill relay If you are not installing starter kil...

Страница 15: ...output to trigger sliding doors power windows or whatever other features you d like Pin 8 Violet Black Trunk negative input This is an optional input that will monitor when the vehicle s trunk has bee...

Страница 16: ...llow Black Tach Sense input Connect this wire to a tach source for Ignition controlled door locks This is option 1 09 setting 3 The doors will lock once the rpms double from what they are programmed a...

Страница 17: ...for trigger door lock systems For additional lock settings review Option Group 1 Pin 5 Blue Black Lock 250mA negative output This is an optional output that will provide a pulse for locking doors Sys...

Страница 18: ...cables 4 to 4 or 4 to 6 Pin antenna cables do not work Do not use both Connector 9 and Connector 10 at the same time Connector 9 CN9 2 Pin Pre wired Thermister Plug optional thermister into this conn...

Страница 19: ...Black Negative ground Pin 2 White 2nd stage negative input Instant trigger Pin 3 Red 12V positive output Pin 4 Yellow 1st stage negative input Warn away Connector 14 CN14 4 Pin Optional Sensor Input...

Страница 20: ...ure Default Setting I Optional Setting II Optional Setting III Optional Setting IV 1 02 Lock Unlock pulse duration 0 8 sec 2 5 sec 0 125 sec 3 5 sec 1 03 Driver s priority unlock Off On 1 04 Double pu...

Страница 21: ...g Input Key Sense Input Disable Arm Disarm when Brown White Wire Triggered Same Time 4 11 Bypass Through RS232 Port ADS Fortin 4 12 Impact Sensor Shock Sensor DAS Sensor 1st Stage Disarm Input 2nd Sta...

Страница 22: ...again within 4 seconds the other doors will unlock The driver s door unlock must be isolated from the other doors and use the blue unlock The Orange Black CN4 will be used for your 2nd Unlock output t...

Страница 23: ...re changes the behavior of the small orange white disarm wire When the feature is turned on it will change the default single pulse to double pulse upon disarm unlock 1 14 Auto Mode EZ GO This feature...

Страница 24: ...grind circuit while the vehicle is remote started if the anti grind circuit is active and the start kill relay is installed in the ignition the relay will buzz while remote started 3 06 Factory Alarm...

Страница 25: ...ation to be set for a specific length of time 1 99 sec only available when using the OP500 4 03 Aux 1 Output Control This feature allows the user to configure the method of which Auxiliary 1 can be ac...

Страница 26: ...2 4 12 Impact Sensor This feature changes between the standard included shock sensor and the optional DAS Digital Adjustable Sensor The DAS has additional programming Please see the Placement and Use...

Страница 27: ...you will need change special option 5 to number 10 This must be done with the OP500 Option Programming CM6300 Option Programming Using the OP500 programmer The OP500 can be used to program any availa...

Страница 28: ...so read this section in its entirety before beginning IMPORTANT Special Option Groups cannot be programmed with a remote the OP500 must be used STEP 1 Select the option menu that contains the desired...

Страница 29: ...for 2 5 seconds then Lock Key for 2 5 seconds Tap Key Button Tap Lock Button Tap Unlock Button Hold Trunk Button for 2 5 seconds Tap Key Button STEP 2 Scroll through menu allowing for 1 parking light...

Страница 30: ...nds Tap Lock Button Tap Unlock Button Tap Key Button Hold Trunk Key for 2 5 seconds Option Menu 4 Lock Key for 2 5 seconds then Lock Key for 2 5 seconds Hold Trunk Key for 2 5 seconds Tap Lock Button...

Страница 31: ...You no longer need to program the remotes before the OP500 will sync I need a ground when armed wire does the control module have one A You can use the ground when armed wire on CN3 that goes to the...

Страница 32: ...the Ignition on and hold buttons 1 and 4 or Lock and Key Start for 2 5 seconds then the parking lights will flash 1 time on the CM6 series showing V 1 and so forth Current version 3 11 should show 3 f...

Отзывы: