Alarm and Starter System
www.firstechdata.com
CM900 Master Guide
Copyright 2016 Fi rst ech ,
LLC.
Page 43
SV 4 -
Accessory:
provides a 250mA (-) negative accessory output on any POC programmed with this
setting.
SV 5 -
GWR (status):
provides a 250mA (-) negative while remote started on any POC programmed with
this setting. Can be used to activate interface modules during the remote start process.
SV 6 -
FAA (Factory Alarm Arm):
provides a 250mA, 800mS (-) negative output with the arm/lock
command on any POC programmed with this setting.
SV 7 -
FAD (Factory Alarm Disarm):
provides a 250mA, 800mS (-) negative output with the
disarm/unlock command on any POC programmed with this setting.
SV 8 -
Horn:
provides a 250mA (-) negative output with output control based on feature 3-08 option
setting when using any POC programmed with this setting.
SV 9 -
Dome light supervision:
provides a 250mA (-) negative output with the disarm/unlock command,
on any POC programmed with this setting, for up to 45 seconds or until ignition is on.
SV 10 -
AUX1:
provides a 250mA (-) negative output (based on feature 4-01 setting) when AUX is
triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC
programmed with this setting.
SV 11 -
AUX2:
provides a 250mA (-) negative output (based on feature 4-02 setting) when AUX is
triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC
programmed with this setting.
SV 17 -
Defrost:
provides a 250mA (-) negative output (based on feature 3-13/3-14 settings) on any POC
programmed with this setting,
when defrost function has been activated (output time based on features 3-13 and 3-14
option settings)
SV 18 -
GWA (ground While Armed):
provides a 250mA (-) negative output on any POC
programmed with this setting, while the system is armed or locked.
SV 21 -
Defrost 2:
provides a 250mA (-) negative pulsed output only on any POC programmed with this
setting, when the defrost output is engaged based on the temp setting of feature 3-13.
NEW* SV 23
–
Hazard Light 2 Control: provides a 250mA (-) negative output on any POC programmed with this
setting that will produce a pulsed output allowing the CM to activate and then deactivate a latching
hazard switch. This will simulate parking light flashes in single flash pulses. This output will also
provide a pulsed parking light output during remote start flashing 1 time every 10 seconds.
SV 25 -
Lock:
provides a 250mA, 800mS (-) negative output on any POC programmed with this setting,
with the lock/arm command.
SV 26 -
Unlock:
provides a 250mA, 800mS (-) negative output on any POC programmed with this
setting, with the unlock/disarm command.
SV 27 -
2nd Unlock:
provides a 250mA, 800mS (-) negative output on any POC programmed with this
setting, when using the driver’s door priority feature. This wire
would be used to unlock the rest
of the doors while unlock should be used to unlock the isolated driver’s door.
Note: this output
can only be activated within 5 seconds after the first unlock command is sent.
SV 28 -
Trunk release:
provides a 250mA, 1 second (-) negative output (output timing based on feature
1-15 on any POC programmed with this setting, with the trunk release command.
SV 29
–
Starter Kill: provides a 250mA (-) negative output on any POC programmed with this setting, while
the system is armed or locked, and during remote start for Anti-Grind.