Alarm and Starter System
www.firstechdata.com
CM900 Master Guide
Copyright 2016 Fi rst ech ,
LLC.
Page 39
4-02 Aux 2 Output: This feature determines the duration of the auxiliary 2 output. (Option 4 allows the
output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update only)
only available when using the OP500)
FO1 - 500mS: This option will provide a (-) negative output for 500 milliseconds (0.5 seconds)
output on any POC programmed with setting 11 (AUX 2)
FO2 - Latched: This option will provide a latched (-) negative output on any POC programmed with
setting 11 (AUX 2). Note: This latched output will reset when ignition is turned on.
FO3 - 500mS pulse + programmable timed output: this option will provide a (-) negative output for
500 milliseconds (0.5 seconds) output on any POC programmed with setting 11 (AUX
2). It will pause for 250 milliseconds then provide a timed output (based off feature 4-02 option 4). Note: to
program the timed output, the user must change feature 4-02 to option 4, then adjust AU2 (AUX
programmable output time) to desired time. To complete the programming steps, feature 4-01 must be
changed to option 3. (i.e. ha
lf second pulse…pause…10 second pulse)
This option can be used to roll
windows up or down on a vehicle that requires a similar action using the driver
’s door key cylinder.
FO4 - Program: This option allows the AUX output time to be programmed for a duration
between 1-99 seconds. Once selected the OP500 will display AU2 and below it will represent the time
the output will provide when triggered. Note: with an OP500 update to v.31 there will be additional
time duration between 1-15 minutes available.
4-03 Aux 1 Output Control: This feature allows the user to configure the method of which Auxiliary 1 can
be activated.
FO1 - Remote: (default) This option allows AUX 1 (output time based on feature 4-01) to be
triggered by any 4 button Firstech remote or drone.
FO2 - With Arm: this option will trigger AUX 2 (output time based on feature 4-02) any time the
CM900 is locked/armed the first time (I.e. if you send a second lock/arm command it will not trigger
again)
FO3 - With Disarm: this option will trigger AUX 1 (output time based on feature 4-01) any time the
CM900 is unlocked/disarmed. Note: the system must be in the armed state when disarming to trigger
AUX 1. (I.e. if the vehicle is already in the unlocked/ disarmed state and you send a second
unlock/disarm command it will not trigger the output)
4-04 Aux 2 Output Control: This feature allows the user to configure the method of which Auxiliary 2 can be
activated.
FO1 - Remote: (default) this option allows AUX 2 (output time based on feature 4-02) to be
triggered by any 4 button Firstech remote or drone.
FO2 - With Arm: this option will trigger AUX 2 (output time based on feature 4-02) any time the
CM900 is locked/armed the first time (I.e. if you send a second lock/arm command it will not trigger
again)
FO3 - With Start: this option will trigger AUX 2 (output time based on feature 4-02) any time the CM900
remote start sequence is activated. Note: this output timing will trigger at the same time as GWR (status
output)