4-05 Secure Aux Output: this feature is designed to prevent accidental activation of the AUX outputs by
requiring an additional step when using any 4 buttons or 2-way LCD Firstech remote.
FO1- On: (default) this option will require the user to perform an additional step before activating AUX
output using any Firstech 4 button or 2-way LCD remote (2way remotes with Roman numeral buttons
will require a 0.5 second tap of button IV before activating any of the AUX outputs.2Way LCD remotes
with lock/unlock/trunk/start icons on the buttons use the start button for the same. 1way remotes require
the user to hold trunk + start buttons for 2.5 seconds before activating AUX outputs.)
FO2- Off: this option will disable the additional step required by the user to activate the AUX outputs.
FO3- On while armed: this feature will only require the user to perform the additional override step
to activate Aux outputs ONLY WHEN the CM900 is ARMED. While the system is disarmed or
unlocked this step is not required.
4-08 Sliding door control for datalink: (must be enabled to allow data to data sliding door control) This
feature will provide an Unlock or Factory Alarm Disarm (FAD) output when triggering the AUX
control using iDatalink Modules (Sliding Doors)
FO1 - Off: (default) This option does not provide an unlock or a FAD output when activating AUX
output control using the iDatalink modules.
FO2 - Unlock and FAD: This option will provide unlock and a FAD output when activating AUX
output control using iDatalink modules.
FO3 - FAD only: This option will only provide a FAD (factory alarm disarms) output when activating
AUX output control using iDatalink modules.
4-10 Positive Input (+): (PINK wire CN3 Pin 11 CM900AS) (RED wire CN3 Pin 11 CM900S) Default to
Trigger Start Input, this feature will determine the input function of the positive input wire
FO1 - Trigger start input: This option will enable to be used as a trigger for activating the remote
start function using a (+) pulse input on the positive input wire CN3 pin 11
FO2
–
Ignition input: This option will enable the positive input wire CN3 pin 11 to be used as an
(B+) Ignition input only and be used for any application where ignition output is not required.
Including remote programming or Ignition controlled door locks
FO3 - (+) keysense input: this option will enable the positive input wire CN3 pin 11 to be used as a
key sense INPUT to the CM. The keysense input will keep the system from passively arming.
FO4 - (+) Glow plug: this option will allow the positive input wire CN3 pin 11 to be used as a glow plug
delay or wait to start input. This is recommended for diesel vehicles that may have a positive analog
glow plug output available.
4-11 UART port 2: This feature will determine the communication protocol of the gray UART port.
FO1 - Drone: (default) This option will allow the grey UART port to communicate using the Drone
data protocol.
FO2 - Fortin: This option allows the grey UART port to communicate using the Fortin data protocol.
Note: there is no longer an “auto detect” feature with the Fortin protocol it must be changed manually.