Alarm and Starter System
www.firstechdata.com
CM900 Master Guide
Copyright 2018 Fi rst ech ,
LLC.
Page 25
#4
Feature
Feature Group 4
Default(I)
Option (II)
Option (III)
Option (IV)
4-1
Aux 1 output
0.5sec
Latch
0.5 sec Pulse + Program
Program
4-2
Aux 2 output
0.5sec
Latch
0.5 sec Pulse + Program
Program
4-3
Aux 1 output Control
By Remote
Arm
Disarm
4-4
Aux 2 output Control
By Remote
Arm
Start
4-5
Secure Aux Output (1 and 2
Only)
On
Off
On While Armed
4-8
Aux 1 and Aux 2 Control for
iDatalink Modules (Sliding
Doors)
Off
Unlock, Factory Disarm,
and Sliding Door
Control
Factory Disarm and
Sliding Door Control
Only
4-10
(+/-) Trigger Start Input
Trigger Start input
Ignition input
keysense input
Glow Plug Input
4-11
DroneMobile or Fortin on 2nd
RS232 Port (Grey Plug)
DR-2000 (Grey
4Pin)
Fortin (Grey 4Pin)
4-12
Impact Sensor
CM900AS ONLY
Shock Sensor
DAS Sensor
1st Stage Disarm Input
| 2nd Stage Double Arm
Input
1st Stage Disarm Input
| 2nd Stage Arm Input
4-14
Low Battery Warning
OFF
ON (at 11.7 Volts)
Low Battery Start
(11.7 V)
S-#1
Feature
Setting Value
1
Diesel timer
3 ~ 99 [seconds]
2
AUX1 output time
1 ~ 99 [seconds], LA(Latch), 1~15 [minutes]
3
AUX2 output time
1 ~ 99 [seconds], LA(Latch), 1~15 [minutes]
4
Cold Start Temperature
-30 ~ 0 [°C] / -22 ~ 32 [°F]
5
Hot Start Temperature
20 ~ 40 [°C] / 68 ~ 104 [°F]
6
Defroster Temperature
0 ~ 13 [°C] / 32 ~ 55 [°F]