Alarm and Starter System
www.firstechdata.com
CM900 Master Guide
Copyright 2016 Fi rst ech ,
LLC.
Page 38
FO4 - Latched for entire runtime: (Remote start runtime based off feature 2-07 option setting) This
feature will provide a latched output for the entire remote start runtime on any POC programmed with
setting 17 (defrost) with timing based off feature 3-12 option settings. Caution: make sure not to latch
rear defrost functions on for too long as it may cause damage to the heating elements in the window.
3-15 Soft Disarm: this feature will enable Factory Alarm Arm (FAA) and Factory Alarm Disarm (FAD)
outputs to trigger when silencing the Compustar siren when sounding with full alarm.
FO1 - Off: (Default) this will keep the standard Compustar soft disarm operation. Soft disarm feature
allows the user to silence the Compustar siren as its sounding with full alarm without fully disarming the
system which may unlock the doors and leave the vehicle unsecure.
FO2 - On: this option will provide a FAD output on both data and analog connections, when the
user taps the unlock/disarm once to silence the Compustar system
while it’s sounding, so it will disarm
any factory alarm that may be sounding as well. In case the FAD function unlocks the doors the CM7 will
send the FAA on both data and analog connections 5 seconds later to make sure the vehicle is
re-locked and secure. (This feature works well with GM, Chrysler, Dodge, Jeep, Toyota, Lexus vehicles
that may have factory security.)
FO3
–
Disarm with 1 press: This option will allow the user to completely disarm the system once it is
sounding on the first unlock command. When set to this option the CM will unlock and send the FAD
commands on the first disarm/unlock press from a Firstech remote.
4-01 Aux 1 Output: This feature determines the duration of the auxiliary 1 output. (Option 4 allows the
output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update only)
(Specific time setting only available when using the OP500)
FO1 - 500mS: This option will provide a (-) negative output for 500 milliseconds (Half second)
output on any POC programmed with setting 10 (AUX 1)
FO2 - Latched: This option will provide a latched (-) negative output on any POC programmed with
setting 10 (AUX 1). Note: This will stay latched until AUX 1 command is sent again to
shut it off.
FO3 - 500mS pulse + programmable timed output: this option will provide a (-) negative output for
500 milliseconds (0.5 seconds) output on any POC programmed with setting 10 (AUX
1). It will pause for 250 milliseconds then provide a timed output (based off feature 4-01 option
4). Note: to program the timed output, the user must change feature 4-01 to option 4, then adjust AU1
(AUX programmable output time) to desired time. To complete the programming steps, feature 4-01
must be changed to option 3.
I.e. 0.5 second pulse…pause…10 second pulse, this option can be used to
roll windows up or down on a vehicle that requires a similar action using the driver’s door key
cylinder.
FO4 - Program: This option allows the AUX output time to be programmed for a duration between
1-99 seconds. Once selected the OP500 will display AU1 and below it will represent the time the
output will provide when triggered. Note: with an OP500 update to v.31 there will be additional
time duration between 1-15 minutes available.