The CM900AS will also provide a door unlock output as soon as the key is turned off or the parking
brake is set (must have parking brake input connected or provide parking brake input from data
module)
FO3 - RPM locking: (Tach input is required for this option to operate properly.) This option will
provide a door lock output at approximately 20% RPM over the programmed idle tach output. (i.e.
program tach at 1000 rpm and doors will lock at a sustained 1200 rpm when moving.) The CM900AS
will also provide a door unlock output as soon as the key is turned off or the parking brake is set
(must have parking brake input connected or provide parking brake input from data module)
1-10 Auto Relock: CM900AS ONLY This Feature allows the CM900AS to relock the doors automatically if the
CM has been unlocked/disarmed but none of the input zones are opened.
FO1 - Off: (default)
FO2 - 30 seconds: This option allows the CM900AS to automatically relock/rearm 30 seconds after
CM7 has been disarmed/unlocked. This will only happen if no zones have not been opened.
FO3 - 60 seconds: This option allows the CM900AS to automatically relock/rearm 60 seconds after
CM7 has been disarmed/unlocked. This will only happen if no zones have not been opened.
FO4 - 5 minutes: This option allows the CM900AS to automatically relock/rearm 5 minutes after it has
been disarmed/unlocked. This will only happen if no zones have not been opened.
1-11 Ignition / Accessory Upon Unlock: This feature will provide an Ignition/Accessory output with unlock/disarm
command. (NOTE: will not provide pulse output with disarm before remote starting)
FO1 - Off: (default)
FO2 - Ignition (+) and (-) pulse output with disarm: This option will pulse both (+) and (-) ignition
wires upon unlock/disarm. Most new Ford vehicles require ignition pulsed + immobilizer with
unlock to disarm the factory alarm.
FO3 - Accessory (+) and (-) pulse output with disarm: This option will pulse both (+) and
(-) accessory wires upon unlock/disarm.
FO4 - Ignition (+) and (-) pulse and Accessory (+) and (-) pulse output with disarm: This option will
pulse both (+) and (-) ignition and accessory wires upon unlock/disarm. Some new Ford vehicles
require ignition and accessory immobilizer with unlock to disarm the factory alarm.
Important: Also used in cases where the vehicle’s radio may turn on and stay on until the door is
opened
when accessory is pulsed.
1-12 2 Way Firstech Remote Updating with OEM Remote action: This feature disables the arming,
disarming, and remote start confirmation updates to any Firstech 2 Way LCD when using an OEM
remote.
FO1 - Off: (default) This feature disables the page back update to the 2 Way Firstech remote when your
interface module provides OEM remote status updates to the CM900.
FO2 - On:
1-13 Double pulse disarm: This feature enables the FAD output. It will pulse 2 times with a single disarm
command.
FO1 - Off (default): Standard single pulse output on the FAD wire. (orange/white by default)
FO2 - On: This feature will generate a double pulse output on the FAD wire. (orange/white by
default)