Topaz RU Installation
-
April 2019
5
3A FLOOR PROTECTION REQUIREMENTS
SOLID CONCRETE FLOOR
If the Fire is to be installed onto a SOLID concrete floor protector (hearth) that has no
heat sensitive materials in its construction it must meet the following
MINIMIUM
dimension as marked A & B from Diagram above:
A
300mm from breast of fire to outer edge of concrete floor protector (hearth)
B
30mm from heat sensitive floor to upper edge of concrete floor protector (hearth)
The minimum width of floor protector must be 820mm and/or 410mm from the centre of
the Fire.