13.  WARRANTIES

 

Terms applicable to Firenzo Wood fires

’ 

warranties (current as at 29

th

 May 2015)

 

 

1

 

Hewitsons  Limited  (company  number  569753)  with  a  specified  address  of  98    

Niven  Street, Onekawa,  Napier (Firenzo) and trading as Firenzo Wood fires gives:    

 

    

-

    a  ten  (10)  year  warranty  but 

ONLY

  for  the  steel  firebox,  fascias  and  cast  iron                  

components of all Firenzo—wood fires.

 

    

-

     a one (1) year warranty for all other parts and finishes of a Firenzo wood fire in-

cluding  its  refractory    linings,  glass,  air  supply  components,  wetback,  seals,  tapes,    

extrusions. 

 

2

 

The  warranty  periods  commence  on  the  original  date  of  sale  of  the  relevant      

Firenzo wood fire to a consumer (please see paragraphs 5 and 8). 

 

3

 

The  warranties  are  given  in  respect  of  any  defects  in  the  specified  Firenzo      

component parts and materials and Firenzo workmanship  that  render the component 
parts and materials unfit for normal domestic use. 

 

4

 

The warranties have qualifying limitations, restrictions and conditions attached to 

them. Please see paragraphs 5, 6, 7, 8, 10 and 14.

 

5

 

Firenzo  gives  the  warranties  only  to  New  Zealand  consumers  as  defined  in  the           

Consumer Guarantees Act 1993.  Please also see paragraph 17. The warranties are          

additional  to  the  rights  available  to  consumers  against  the  manufacturer  under  the 

Consumer  Guarantees  Act  1993.  To  the  fullest  extent  permitted  at  law,  no  other      

warranties or           guarantees, express or implied, are assumed or given by Firenzo 

to any person with respect to the quality, merchantability, description or fitness for pur-

pose or use of Firenzo wood fires or their component parts and materials. 

 

6

 

Firenzo  is  not  liable  for,  and  to  the  maximum  extent  permitted  by  law  excludes 

any          liability  for,  any  consequential  loss  or  damage  arising  out  of  the  installation, 

ownership or use of a Firenzo wood fire. To the extent such liability cannot lawfully be 

excluded, Firenzo

s     liability is limited to the purchase price paid for the Firenzo wood 

fire.

 

7

 

The warranties do not apply to:

 

         

-

  normal wear and tear.

 

         

-

 performance issues or limitations affecting a Firenzo wood fire arising out of: 

 

         

-

 prevailing site conditions such as downdraughts or insufficient draw.

 

         

-

 or from, incorrect servicing adjustments or incorrect flue.

 

The  warranties  are  

valid  only  if  the  original  purchasing  consumer  completes  and  returns  a  copy  of  the    

prescribed Warranty Registration Card to Firenzo at  the specified address, dated the 

sale  date,  and  specifying  the  residential  address  where  the  Firenzo  wood  fire  is        

installed.    The  original  purchasing  consumer  should  keep  their  part  of  the  Warranty 

Registration Card for validating warranty claims.

 

9

 

The warranties may be assigned to other consumers (as defined in the Consumer    

Guarantees Act 1993) on any sale of the residential property where a Firenzo wood fire 

has been installed.  

 

Содержание Topaz RURAL

Страница 1: ...e use of a NZ Home Heating Association solid fuel Fire installation technician SFAIT or other suitably qualified person The Fire and Flue System must be installed in accordance with AS NZS2918 All Ins...

Страница 2: ...t of Flue System Outlet 11 12 7 Typical Insulation Requirement 13 24 8 Clearances Floor Protector for a Zero Clearance Box Built In Fire Canopy 25 Installation of Kaowool ISB Insulation 26 Assembly In...

Страница 3: ...AEROSOLS in the vicinity of this FIRE when it is operating Use caution when reloading with fuel Do NOT attempt to load fuel into the Fire when the fire inside the stove is at or near its peak Do NOT b...

Страница 4: ...facturer should be consulted in the first instance Strict adherence to these instructions will meet these standards Any variation from these installation instructions or any doubt about them must be c...

Страница 5: ...heat sensitive materials in its construction it must meet the following MINIMIUM dimension as marked A B from Diagram above A 300mm from breast of fire to outer edge of concrete floor protector heart...

Страница 6: ...nt to check the condition of your masonry chimney Ensure any cracks are sealed loose masonry repaired and the chimney swept Check the dimensions of your fireplace opening are adequate to accept the ne...

Страница 7: ...and 10 6 Now that the Firebox and Flue are in position place 25mm white Kaowool blanket supplied on top of casing 7 As this fire sources its combustion air from the chimney cavity enclosure the fire M...

Страница 8: ...The chimney plate must be weather sealed with silicone or mortar 4 Install chimney liner on top of the chimney plate 5 Ensure flue is extended over the chimney liner by 180mm Secure top spacer bracke...

Страница 9: ...Topaz RU Installation April 2019 9 6 INSERT FLUE SYSTEM FOR INSTALLATION IN A ZERO CLEARANCE BOX BOX Built in Fire Canopy...

Страница 10: ...f the floor protec tor 2 The flue cowl must be at least 600mm above the highest point of the roof if within 3 metres of it or 1 metre above the roof penetration if more than 3 metres from the ridge 3...

Страница 11: ...nstallation April 2019 11 7 TYPICAL INSULATION REQUIREMENTS FOR MASONRY Vent 50x100 minimum 450 Minimum Gap so Fascia fits is 300mm If lower than 150mm Insulated Hearth required If greater than 150mm...

Страница 12: ...nd masonry enclosure at the FRONT ONLY to a maximum depth of 80mm UNDER NO CIRCUMSTANCES SHOULD THE AIR SUPPLY INTO THE AIRPORTS ON THE SIDE OF THE FIRE BE RESTRICTED SIDE PILLAR CLEARANCE The minimum...

Страница 13: ...Built in Fire Canopy A ZERO CLEARANCE BOX Built in Fire Canopy IS REQUIRED IF THE FIRE IS NOT BEING INSTALLED INTO A MASONRY FIREPLACE For built in Zero Clearance Box Built in Fire Canopy installatio...

Страница 14: ...Topaz RU Installation April 2019 14 ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 15: ...Topaz RU Installation April 2019 15 ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 16: ...Topaz RU Installation April 2019 16 ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 17: ...Topaz RU Installation April 2019 17 1350 1355 1000mm 1460 300 min 1000mm 300 min 700 min ZERO CLEARANCE BOX Built in Fire Cano...

Страница 18: ...Topaz RU Installation April 2019 18 700mm to Ceiling ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 19: ...Topaz RU Installation April 2019 19 1000 ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 20: ...Topaz RU Installation April 2019 20 ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 21: ...Topaz RU Installation April 2019 21 ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 22: ...learance to framing all round Zero clearance must sit on 40mm base provided Zero Flue starter must be used Minimum height to first framing 700mm The minimum height must be 300mm Minimum height to ceil...

Страница 23: ...of 20mm of Insulation board Promatech H Eterpan LD Pacbld Pro or product of similar thermal resistance and tiles slate or similar with sealed joints on top surface to protect from spilt ash embers FLO...

Страница 24: ...the clearance from the top of the fire box to the ceiling is no less than 1500mm The ash floor protector must be of a minimum of 450mm from the fire breast the width must be no less than 840mm Positio...

Страница 25: ...Topaz RU Installation April 2019 25 INSTALLATION OF KAOWOOL AND ISB INSULATION IN A ZERO CLEARANCE BOX Built in Fire Canopy...

Страница 26: ...EALAND BEING AN EARTHQUAKE PRONE COUNTRY IT IS IMPORTANT TO ANCHOR THE INSERT DOWN IN CASE OF MOVEMENT Restraint points are provided through the fires two front legs See diagram below 6 Install Flue a...

Страница 27: ...or carefully and place small pieces then larger logs on top 6 Close door tight and leave Air Control on HIGH for some 30 minutes The value in establishing this technique is that you are providing an e...

Страница 28: ...st empty Fire set at the same position Remember you only get out of any Fire what you put into it The better the fuel the better the Fire Do NOT burn plastic household refuse or driftwood This will vo...

Страница 29: ...d on the paintwork use Stovebright Metallic Black paint to retouch taking note of the manufacturer s instructions for spraying Never spray a hot fire FIRE BRICKS The internal fire bricks on the sides...

Страница 30: ...material for the glass should be replaced at this time also NEVER place glass directly against the door Without the insulation seal tape in place the glass is likely to shatter Your Firenzo Dealer wi...

Страница 31: ...arantees Act 1993 To the fullest extent permitted at law no other warranties or guarantees express or implied are assumed or given by Firenzo to any person with respect to the quality merchantability...