MAINTENANCE
I115SS
Rev. 001
22/12/2014
45/58
5. MAINTENANCE
5.1. ROUTINE MAINTENANCE
Carrying out maintenance at regular intervals is extremely important to ensure the floor scrubber efficiency
and prolong its working life to the end of the warranty time. The performed services should be logged in
writing by using the special form contained in this manual.
Trained personnel only may service the machine and in particular, its electric and
electromechanical parts. Specific tools and equipment should be used according to the
type of service.
For servicing and spare part requirements exclusively contact FIORENTINI S.p.A. (point
7.1. / 7.2.).
OPERATION
TASKS
FREQUENCY
Cleaning
Clean the recovery tank
Daily
Do not use corrosive substances.
Do not use pressurised water
jets.
Check the cleanness of the suction pipes
and squeegee
Check and clean the clean water cone filter
Weekly
Checks
Check the condition of the squeegee rubber
suction blades
Every 2 weeks
Check the battery water level
Weekly
Check the clean water tank filter (OPTIONAL)
Monthly
Check the braking system
Every 3 months
Check battery cable connections
Every 6 months
Check the brushes of each motor
Yearly
Check the safety devices
Check the wiring system
Yearly
5.2
BATTERY MAINTENANCE (battery powered version) …….…...…........…....
The operator is expected to check the battery state of charge while the machine is in operation via
the battery charge indicator on the dashboard
Leave the battery compartment open during charging
Do not use naked flames or smoke near batteries
Warning: battery acid is corrosive
Do not produce sparks near batteries
Battery gases are explosive
Do not reverse battery polarity