18
TIG welding with HF Arc
generation is very similar to Lift-Arc
welding. The only difference is, the
electrode does not need to make contact
with the workpiece. It only needs to be app.
3-4 mm away from the workpiece while the
torch button is being pressed to generate
an arc before contact is made.
6.3.6 Welding Parameter Setting
This description often refers to Figure 1.
Set the welding current turning knob 25. The
value selected will be displayed on panel 13.
App. 1 minute after being adjusted, the new
value is memorised for future operations.
Many other welding parameters can also be
adjusted. Press button 14 (“Set”) until the LED
relating to the required parameter lights up
(LEDs 3 to 10).
The value of that parameter (or feature) can
be adjusted used knob 25 (the value will be
displayed on panel 13).
The adjustments are memorised pressing
button 14 (“Set”) or automatically in app. 1.5
seconds.
Note 1:
12 frequencies can be selected
(0.3Hz, 0.5Hz, 1Hz, 3Hz, 5Hz, 10Hz, 15Hz,
20Hz, 30Hz, 50Hz, 80Hz, 100Hz.) Three or
four duty cycle values can be selected for
each frequency, as per the following Table.
LED Nome
Pre
gas
Is
Su
Pulse
I2
Sd
If
Post
gas
Tempo di Pre-Gas
(Tempo in cui viene
fatto fluire il gas
prima di iniziare la
saldatura)
Corrente iniziale
(corrente al
momento della
pressione del
pulsante torcia e
corrente di
back-ground)
Slop-UP Time
(tempo in cui la
corrente passa dal
valore Is al valore I2)
Frequenza e
duty-cycle
di pulsazione
(frequenza di
ripetizione della
pulsazione)
Corrente di saldatura
Slop-Down Time
(tempo in cui la
corrente passa dal
valore I2 al valore If)
Corrente finale
(corrente di fine
saldatura)
Tempo di Post-Gas
(Tempo in cui viene
fatto fluire il gas
dopo la fine della
saldatura per
raffreddare la torcia)
6.2.3
0 - 20s
0.5s
6.2.3
6.2.4
da 5A al
valore I2
20 A
6.2.3
0 -20 s
0,2 s
6.2.4
3 – 100Hz
(Nota 2)
30Hz
6.1
6.2
6.2.3
0 – 20 s
2 s
6.2.3
6.2.4
da 5A al
valore I2
20 A
6.2.3
0 – 20 s
5 s
TT258:
5 – 255A
100A
TT305:
5 - 300
100A
DESCRIZIONE Descr.
Paragrafo
Range di
variazione
Valore
di
default
3
4
5
6
7
8
9
10
Frequenza
selezionata
Duty-Cycle
Visualizzazione sul
display 13
0.3Hz
0.3Hz
0.3Hz
0.3Hz
0.5Hz
12.5%
25%
50%
75%
12.5%
25%
50%
75%
12.5%
25%
50%
75%
25%
50%
75%
25%
50%
75%
0.31
0.32
0.33
0.34
0.51
0.52
0.53
0.54
1.1
1.2
1.3
1.4
3.1
3.2
3.3
5.1
5.2
5.3
0.5Hz
0.5Hz
0.5Hz
1Hz
1Hz
1Hz
1Hz
3Hz
3Hz
3Hz
5Hz
5Hz
5Hz
Figure 8