XIV
•
The radioactive material is sealed by double fusion welds into
a stainless steel capsule. At manufacture, and again at instal-
lation, this capsule is subjected to rigorous tests capable of
detecting the leakage of five millionths of one percent of the
contents. Therefore as long as the source capsule’s integrity is
not compromised, radioactive material cannot be released.
•
As an additional precaution, the regulatory agencies require
that a licensed individual inspect the radiation source and the
shutter mechanism and conduct a leak test every 36 months.
Radiological Safety Guidelines
You have been supplied with a copy of the Rules, Regulations and
Registration Requirements for your location, however, the
following is a brief synopsis of the general requirements.
1.
Understand the rules, regulations, and registration require-
ments regarding the use of this equipment at your location. A
copy of this is supplied with your FT-50.
2.
Do not open or tamper with the enclosure containing the radio-
isotope source.
3.
Do not place your hands, or any other body part, between the
source and detector when the safety shutter is open.
4.
Have inspection and wipe tests performed by a properly
licensed technician at the specified 36 month intervals (Indus-
trial Dynamics' Service Technicians can do this). Keep a record
of each inspection and test.
5.
In the case of an accident which crushes or punctures the
source enclosure, seal off the area, cover the FT-50 and
surroundings with a plastic sheet or tarpaulin and call Indus-
trial Dynamics immediately.
6.
Do not relocate or dispose of the FT-50 without proper
approval. A licensed technician must perform this function.
7.
If you have any questions, call Industrial Dynamics.
Radiation Measurement Testing Data
1.
All measurements were taken with Technical Associates Model
Pug-1 survey meter. The meter was cross calibrated against an
air ionization chamber survey meter whose response was
corrected against an Americium-241 test source.
Industrial Dynamics Company, Ltd.
Document 40255-0600
Содержание FT-50c
Страница 1: ...FT 50c Service and Technical Reference Manual 40255 0600 ...
Страница 2: ...FT 50c Fill Level Inspector Service and Technical Reference Manual Document 40255 0600 ...
Страница 13: ...FT 50 Fill Level Inspector Service Manual XII Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 19: ...FT 50 Fill Level Inspector Service Manual XVIII Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 21: ...FT 50 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 33: ...FT 50 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 35: ...FT 50 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 39: ...FT 50 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 41: ...FT 50 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 71: ...FT 50 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 99: ...FT 50 Fill Level Inspector Service Manual 5 4 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 139: ...FT 50 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 141: ...FT 50 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 185: ...FT 50 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 191: ...FT 50 Fill Level Inspector Service Manual 7 8 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 219: ...FT 50 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 227: ...FT 50 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 237: ...FT 50 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd Document 40255 0600 ...