This is the operating instruction for the AKAS®
models
AKAS®-LC IIM, AKAS®-LC IIF
Special instructions for each model are provided with its individual model marking.
Attention is drawn to all safety instructions by this symbol. Particular attention must be paid to such instructions.
These operating instructions provide to the user important information concerning the correct use of the AKAS®.
These instructions are a component of the light barrier concerned. It is essential that they are easily available at
the location where the safety light barrier is installed. Before the initial operation of the AKAS®, all requirements
detailed in these operating instructions must be observed. Other relevant regulations and the requirements of
the employers' liability insurance associations have also to be complied with.
Mounting, initial operation and maintenance may only be performed by qualified persons.
Light barriers do not protect anybody from machine-caused flying objects.
The AKAS® protects fingers and hands that hold the sheet during the operation.
Therefore it does not protect
during any fast engagement between the bending punch and the matrix short time before those are
closed. The protection function of the system is cancelled when the Muting lamp is on.
The front beams E1 which are turned to the operator before the bending line do not protect, if the box-
bending function has been activated earlier.
With the integration of a AKAS ® safety system, the standard should be strictly complied with the
European Standard (EN12622).
Protection circuits and Emergency can only stop the opening movement when the movement is
interupted with the RXOK outputs.
5
Read the operating in-
structions
Qualified Personnel
Safety warning
A-Test:
putting into operation
B-Test: daily check
(at least every 24 hours)
Safety Instructions
Please observe always
2
Doku Nr. 995 Stand 1.12.2011 / Aui
A-TEST when putting into operation
The setting must be done in a way that the following test will be passed:
- The B-Test must be done for safety reasons each 5 times on the left end and on the right end of the
upper tool.
- The press brake must be equipped completely with the heaviest
upper tool.
- Start of the closing movement from the maximum top dead centre (T.D.C)
At the beginning of each shift and after each change of tools, the AKAS® press brakes protection
must be checked as follows (see also pr EN 12622.2002):
Test must be carried out at both left and right ends of the bending punch.The punch must not touch the
step-shaped test rod.
a.) Place the test piece in position "10" on the lower tool. Select the box bending function if you use a
system of the AKAS®3... product family.
Now start the close down movement.
b.) The press brake stops.
c.) The test piece must be placed in position "15" under the upper tool. In this position ("15") the test
piece may not touch the upper tool.
d.) Drive up the press brake. Place the the test piece in position "35" on the lower tool. Select the nor-
mal bending function if you use a system of the AKAS®3... product family.
Now start the close down movement.
e.) The press brake must be stopped in a way that the test piece ("35") may not touch the upper tool.
f.) Move the test piece ("14") along the tip of
the upper tool. The AKAS®-II receiver has to
remain in the interrupted (LS unterbrochen /
interrupted = red LED) state.
fig. 5/ 2
a.
b.
c.
d.
e.
f.
Stop
Stop
LS interrup-
ted
10
15
35
14
fig. 5/1