Terms
The press brake protection AKAS® is an electrosensitive protective device (ESPE).
ESPE is characterised by the fact that a hazardous motion becomes interrupted or prevented if the
light beams
produced between the transmitter and receiver unit are interrupted.
AKAS ® meets Safety Category 4 according to EN 954, e PL (Performance Level) according to EN ISO 13849-1:
2008 and SIL 3 according to EN 62061:2005 Devices to safety category 4, PL e, SIL 3 are self-monitoring
sensitive protective equipment and provide the highest Safety class among the sensitive protective equipment.
The electrosensitive protective device (ESPE) switches automatically into the "safe state" when it is faulty.
Maximum distance between transmitter and receiver is 6 m ( For longer range please get in contact with
Fiessler Elektronik or your local dealer).
The part of the hazardous motion still taking place after interrupting the light beam.
The distance covered during the overrun (e.g. by the ram of a press).
The duration of the overrun traverse.
The time that elapsed after light beam interruption until the switching action occurs.
Before every release of the output contacts the contactor control is checking whether the switching elements connec-
ted (relays, contactors or valves) have been released. A renewed release of the
output contacts is only possible if the switching elements connected have been released. Thus a dangerous failure of
switching-elements (relays, contactors or valves) caused by the hazardous motion is prevented.
After initial operation or after a power supply interruption a renewed "enabling" is blocked by the start interlock.The re-
newed release of the switching unit is only possible by closing and opening of the start entry.
The restart interlock prevents any automatic releasing of the switching outputs after an interruption and
re-enabling of the light beam (e.g. when penetrating the light beam).
Short-time safe by-pass of the press brake protection AKAS® during material movement, i.e. during a plate bending
process.
By-pass of the receiver unit E1 during a box-bending process.
44
Electrosensitive protective
equipement
Safety category 4
PL e, SIL3
Self-monitoring
Standard Installation range
Overrun
Overrun traverse
Overrun period
Response time
Valve or contactor control
Start interlock
Restart interlock
Muting
Box-bending
11
Doku Nr. 995 Stand 1.12.2011 / Aui
FIESSLER
E L E K T R O N I K