27
Terminals
AKAS®-LCF
Receiver
transmitter
Electrical connections - Description / Wiring diagrams
6
-with selectable safety functions
6.5
Doku Nr. 995 Stand 1.12.2011 / Aui
1
2
3
4
5
6
Terminals of the transmitter
Nr
1
designation
+S
meaning
+Ub transmitter
2
6
-S
Erde
-Ub transmitter
functional ground
Terminals of the Receiver AKAS®-LCF
position of HEX-switches
B8 B8 oder F8 F8
position of HEX-switches
00 00
Nr
1
designation
Erde
meaning
functional ground
signal level
signal level
2
3
4
5
+Ub 24VDC
-Ub 0V
power supply
power supply
RS 232 GND
-Ub Sender
message output (State-/error)
connection for -Ub AKAS transmitter
6
7
8
9
+Ub Sender
FUS
connection for +Ub AKAS-transmitte
/key-operated switchfor adjustment
input
Start / Stop
closing stroke
FUO
SGS
input
Start / Stop
closing stroke
input
monitoring of slow speed position
10
11
12
13
SGO
SP
input
monitoring of slow speed position
input
safety point
SGA
NLW
output
slow speed request
input
overrun traverse control input
+24V if foot pedal is activated or
key-operated switch is on
0V Press brake stop
+24V Press brake close
+24V if FUS is triggered
or key-operated switch is on
0V Press brake stop
+24V Press brake close
+24V Press brake stop
0V Press brake close
0V: at fast speed
+24V: at slow speed
0V Press brake stop
+24V Press brake close
0V: at fast speed
+24V: at slow speed
+24V: at fast speed
0V: at slow speed
0V within fast speed range
+24V within slow speed range
0V: at fast speed
+24V: ar slow speed
0V: at fast speed
+24V: at slow speed
0V only slow speed permitted
+24V fast/slow speed possible
0V: if activated by cam switch
+24V if not activated by cam
switch
0V only slow speed permitted
+24V fast/slow speed possible
14
15
16
17
EDMS
EDMO
input
monitoring of the Stopvalves
input
monitoring of the Stopvalves
NA1
NA2
input
Emergency OFF / rear metal grid
input
rear / lateral metal grid
18
19
20
21
NA3
S_EU2K
Eingang
Emergency OFF / lateral metal grid
+Ub transmitter EU2K 500/2
rear
guard with antivalent switching light grid
HUSP
RXOK1
output
request for higher switch-
over point
output
drive rear stopper emergeny-OFF
0V at stop
+24V at closing stroke in fast
0V: at closing stroke
+24V: at Stop
+24V if grid is closed i.e.
emerg. OFF is not activated
+24V if grids are closed
+24V if grid is closed i.e.
emerg. OFF is not activated
+24V: if box-bending is
selected
+24V: if enabled
+24V: if box-bending is
selected
22
23
24
25
RXOK2
OSSD1
output
drive rear stopper emergeny-OFF
safety output
release of the closing stroke
OSSD2
KAST
safety output
release of the closing stroke
input
box bending
26
RS 232 out messaage output (State-/error)
+24V: if enabled
+24V: if enabled
+24V: if enabled
+24V: if enabled
+24V pulse min. 100 ms
+24V: if enabled
+24V pulse min. 100 ms
26
3
4
5
6
7
8
9
10
11
12
13
25
24
23
22
21
20
19
17
16
15
14
18
2
1
AKAS®-LC II F
FIESSLER
E L E K T R O N I K
Pin 1
Pin 14