background image

1

10/2015 EN

ENGLISH

PRSU/M2SI

Multifunctional Downstream Device

0266691

Before installing, operating or maintaining the device, read and 

understand this manual.

DANGER

ATTENTION

Dangerous tension.

Danger to life or serious injury.

Disconnect the system and device from the power before 

starting work.

A secure device function is only guaranteed with certified 

components!

Hints

The  products  described  here  are  designed  to  perform  safety-related 

functions  as  part  of  an  overall  plant  or  machine.  A  complete  safety-

related  system  usually  contains  sensors,  evaluation  units,  signaling 

devices and concepts for safe shutdowns. It is the responsibility of the 

manufacturer  of  a  system  or  machine  to  ensure  the  correct  overall 

function.  Tapeswitch  is  unable  to  guarantee  all  the  features  of  a 

complete system or machine that was not designed by Tapeswitch. The 

overall concept of the controller in which the device is integrated must be 

validated  by  the  user.  Tapeswitch  also  assumes  no  liability  for 

recommendations that are given or implied by the following description. 

Due  to  the  following  description,  no  new  warranty,  warranty  or  liability 

claims beyond the general tapeswitch delivery conditions can be derived.

Safety Regulations

-

-

The device may only be installed and commissioned by

knowledgeable persons who are familiar with this operating manual

and with the applicable regulations on occupational safety and

accident prevention.

Observe the VDE and local regulations, especially with regard to

protective measures.

- Opening the case or unauthorized modifications will invalidate any

warranty.

- Mount the device in a control cabinet with degree of protection IP 54 or

better; Dust and moisture can otherwise lead to impairments of the

functions.

- Provide sufficient protective wiring at all output contacts for capacitive

and inductive loads.

- The safety function must be triggered during commissioning.

If used as directed and in accordance with this manual, no residual risks 

are known. Failure to do so may result in personal injury and property 

damage.

The PRSU / M2SI is used for the safety-related release and interruption of 

a safety circuit. It can be used to protect people and machinery in 

applications with emergency stop pushbuttons, safety gates, self-test (type 

4) photocells in accordance with IEC / EN 61 496-1, two-hand switches for

metalworking presses, and other working machines with dangerous 

closing movements (Type III C according to EN 574) and for safety-related 

safety mats, safety edges and band switches.

Intended Use

Device Properties

Your advantages

two independent safety functions adjustable

out:

-

Safety mat / strip, band switch

-

photocell

-

Emergency stop switch

-

Safety gate

-

two-hand control

-

Antivalent switch

only one device type, two safety functions at the same time

manual or automatic start 

 

C

haracteristics

complies

- Performance Level (PL) e and Category 4 according to EN ISO

13849-1: 2008

- SIL claim limit (SIL CL) 3 according to IEC / EN 62061

- Safety Integrity Level (SIL) 3 according to IEC / EN 61508 and IEC /

EN 61511

according to EN 50156-1 for combustion plants

Line fault detection on the ON button

Activation via on-button or automatic on-function

with or without cross-circuit detection

2-channel design

positively driven output contacts

Output: 2 NO contacts per safety function

1 semiconductor output per safety function

LED indicators operating voltage, safety function 1, 2 and error

Device connections: pluggable terminal blocks with screw terminals

Safety  Instructions

ATTENTION - AUTOMATIC START!

According to IEC / EN 60 204-1 point 9.2.5.4.2, no automatic start must 

be made after stopping in an emergency. Therefore, in the modes with 

automatic start, a higher-level control must prevent an automatic start 

after an emergency stop.

Terminals

Terminal Designation

Signalbeschreibung

A1 +

DC24V

A2

0V

13, 14, 23, 24, 
43, 44, 53, 54

Normally open for release 

circuit

38, 68

Semiconductor monitoring output

GND

Reference potential for 

semiconductor signal outputs

S11, S21, S31, S41

control outputs

S12, S22, S32, S42, 
ST1, ST2, RES

control outputs

ORIGINAL

All information in this manual corresponds to the technical state at the time of issue. We reserve 

the right to make technical improvements and changes at any time.

Operating Manual

E-mail: [email protected] • Web: www.tapeswitch.com

Phone: 631-630-0442 • Toll Free: 800-234-8273

Содержание PRSU/M2SI

Страница 1: ... is used for the safety related release and interruption of a safety circuit It can be used to protect people and machinery in applications with emergency stop pushbuttons safety gates self test type 4 photocells in accordance with IEC EN 61 496 1 two hand switches for metalworking presses and other working machines with dangerous closing movements Type III C according to EN 574 and for safety rel...

Страница 2: ...his device presents no known residual risks Non observance may lead to personal injuries and damages to property The PRSU M2SI is used to enable and interrupt a safety circuit in a safe way It can be used to protect people and machines in applications with e stop buttons safety gates light curtains with selftesting Type 4 acc to IEC EN 61 496 1 2 hand controls for presses as well as other producti...

Страница 3: ... A new reset is only possible when the reset signal had been switched off temporarily If an external failure occurs because both input channels of a safety function did not switch on or off within the simultanious time a reset is only possible if both channels are switched to off state after removing failure cause If an external failure occurs in only one safety function only this function will be...

Страница 4: ...acts 5 Start up at UN 65 ms Release delay at UN and disconnecting the supply 40 ms Release delay at UN and disconnecting S12 S22 or S32 S42 60 ms Two hand control 3 Start up at UN 110 ms Release delay at UN and disconnecting the supply 40 ms Release delay at UN and disconnecting S12 S22 or S32 S42 60 ms simultaneity demand max 0 5 s Safety mat 4 Safety Edge Tapeswitch Start up at UN 85 ms Release ...

Страница 5: ... 15 55 C Storage 25 85 C Altitude 2 000 m Clearance and creepage distance rated impuls voltage pollution degree 4 kV 2 IEC 60 664 1 EMC Electrostatic discharge ESD 8 kV air IEC EN 61 000 4 2 HF irradiation 10 V m IEC EN 61 000 4 3 Fast transients 2 kV IEC EN 61 000 4 4 Surge voltage between wires for power supply 1 kV IEC EN 61 000 4 5 between wire and ground 2 kV IEC EN 61 000 4 5 HF wire guided ...

Страница 6: ...7 Auto Start Safety function 2 see page 7 Manual Start Operating mode 5 MANUAL with common button Safety function 1 see page 7 Manual start with common button Safety function 2 see page 7 Manual start with common button Application examples with safety function PRSU M2SI PRSU M2SI ...

Страница 7: ...754 S22 S11 S12 S12 S1 M11124 S21 S22 S11 S12 M10753 Not Aus S21 Fct Safety mat Safety edge Tape switch 4 with cross fault detection SIL 3 PL e Cat 4 Fct Exclusive or contacts 5 with cross fault detection SIL 3 PL e Cat 4 Fct E Stop 6 without cross fault detection SIL 3 PL e Cat 4 1 S21 S22 S11 S12 Schiebeschutztür geschlossen M10752 OSSD1 OSSD2 S22 S21 S11 S12 Sender Empfänger DC 24V 0V M10751 Fc...

Страница 8: ... A 0 6 x 3 5 0 5 Nm 5 LB IN M10248 A A 7 mm 1 x 0 2 2 5 mm2 1 x AWG 24 to 12 2 x 0 2 1 0 mm2 2 x AWG 24 to 18 M10249 A A 7 mm 1 x 0 25 2 5 mm2 1 x AWG 24 to 12 2 x 0 25 1 0 mm2 2 x AWG 24 to 18 M10250 A A 7 mm 1 x 0 2 2 5 mm2 1 x AWG 24 to 12 2 x 0 2 1 5 mm2 2 x AWG 24 to 16 Dimensions dimensions in mm A B PRSU M2SI 110 1 22 5 M4345_a M4345_a 35 115 3 0 0 7 122 6 0 0 7 B A 106 9 Mounting disassemb...

Страница 9: ... variants are available on request The safety relevant data of the complete system has to be determined by the manufacturer of the system Approvals and Markings Demand to our device based on the evaluated neccessary safety level of the application Intervall for cyclic test of the safety function EN ISO 13849 1 PL e with Cat 3 or Cat 4 once per month PL d with Cat 3 once per year IEC EN 62061 IEC E...