Tapeswitch PRSU/M2SI Скачать руководство пользователя страница 2

2

10/2015 EN

Operating instructions 

ENGLISH

Before installing, operating or maintaining this device, these instructions 
must be carefully read and understood.

DANGER

CAUTION

Dangerous voltage.
Electric shock will result in death or serious injury.

Disconnect all power supplies before servicing equipment.

Safe operation of the device is only guaranteed when using certified 
components!

Important Notes

The product hereby described was developed to perform safety functions 
as a part of a whole installation or machine. A complete safety system 
normally includes sensors, evaluation units, signals and logical modules 
for safe disconnections. The manufacturer of the installation or machine is 
responsible for ensuring proper functioning of the whole system. Tapeswitch  
cannot guarantee all the specifications of an installation or machine that 
was not designed by Tapeswitch. The total concept of the control system 
into which the device is integrated must be validated by the user. Tapeswitch 
also takes over no liability for recommendations which are given or implied 
in the following description. The following description implies no modification 
of the general Tapeswitch terms of delivery, warranty or liability claims.

 

Safety Regulations

- This device must be installed and operated by trained staff who are

familiar with these instructions and with the current regulations for safety 
at work and accident prevention.

- Pay attention to applicable local regulations, especially regarding safety 

measures.

- Opening the device or implementing unauthorized changes voids any

warranty

- The unit should be panel mounted in an enclosure rated at IP 54 or

superior. Dust and dampness may lead to malfunction.

- Adequate fuse protection must be provided on all output contacts with

capacitive and inductive loads.

- The safety function must be triggered during commissioning

When used in accordance with its intended purpose and following these 
operating instructions, this device presents no known residual risks. Non-
observance may lead to personal injuries and damages to property. 
The PRSU/M2SI is used to enable and interrupt a safety circuit in a safe 
way. It can be used to protect people and machines in applications with 
e-stop buttons, safety gates, light curtains with selftesting (Type 4) acc. to
IEC/EN 61 496-1, 2-hand controls for presses as well as other production
machinery with dangerous closing action (Type III C to EN 574) and for
safety mats, safety edges and tape switches.

Designated Use

Main Features

Your Advantage

  2 independent, separately adjustable safety functions:

- Safety mat / Safety edge / Tapeswitch
- Light curtain
- E-Stop
- Safety gate
- Two-hand control

- Exclusive or contacts

Only one device, two safety functions at the same time

Manual or auto start

Features

According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511

Acc. to EN 50156-1 for furnaces

Line fault detection on On-button:

Manual restart or automatic restart

With or without cross fault monitoring

2-channel

Forcibly guided output contacts

Output: 2 NO contacts per safety function

1 semiconductor output per safety function

LED indicator for operation, safety function 1, 2 and failure

Removable terminal strips: plug in screw terminals

Safety Notes

ATTENTION - AUTOMATIC START!

According to IEC/EN 60 204-1 part 9.2.5.4.2 and 10.8.3 it is not allowed 

to restart automatically after emergency stop. Therefore the machine 

control has to disable the automatic start after emergency stop.

Connection Terminals

0266691

Terminal designation

Signal designation

A1 +

DC 24 V

A2

0 V

13, 14, 23, 24, 
43, 44, 53, 54

Forcibly guided NO contacts for 
release circuit

38, 68

Semiconductor monitoring output

GND

Reference potential for 
Semiconductor monitoring output

S11, S21, S31, S41

control output

S12, S22, S32, S42, 
ST1, ST2, RES

control input

 PRSU/M2SI

Multifunctional Control Unit 

ORIGINAL

All technical data in this manual relate to the state at the moment of edition. We reserve the right 
for technical improvements and changes at any time.

Содержание PRSU/M2SI

Страница 1: ... is used for the safety related release and interruption of a safety circuit It can be used to protect people and machinery in applications with emergency stop pushbuttons safety gates self test type 4 photocells in accordance with IEC EN 61 496 1 two hand switches for metalworking presses and other working machines with dangerous closing movements Type III C according to EN 574 and for safety rel...

Страница 2: ...his device presents no known residual risks Non observance may lead to personal injuries and damages to property The PRSU M2SI is used to enable and interrupt a safety circuit in a safe way It can be used to protect people and machines in applications with e stop buttons safety gates light curtains with selftesting Type 4 acc to IEC EN 61 496 1 2 hand controls for presses as well as other producti...

Страница 3: ... A new reset is only possible when the reset signal had been switched off temporarily If an external failure occurs because both input channels of a safety function did not switch on or off within the simultanious time a reset is only possible if both channels are switched to off state after removing failure cause If an external failure occurs in only one safety function only this function will be...

Страница 4: ...acts 5 Start up at UN 65 ms Release delay at UN and disconnecting the supply 40 ms Release delay at UN and disconnecting S12 S22 or S32 S42 60 ms Two hand control 3 Start up at UN 110 ms Release delay at UN and disconnecting the supply 40 ms Release delay at UN and disconnecting S12 S22 or S32 S42 60 ms simultaneity demand max 0 5 s Safety mat 4 Safety Edge Tapeswitch Start up at UN 85 ms Release ...

Страница 5: ... 15 55 C Storage 25 85 C Altitude 2 000 m Clearance and creepage distance rated impuls voltage pollution degree 4 kV 2 IEC 60 664 1 EMC Electrostatic discharge ESD 8 kV air IEC EN 61 000 4 2 HF irradiation 10 V m IEC EN 61 000 4 3 Fast transients 2 kV IEC EN 61 000 4 4 Surge voltage between wires for power supply 1 kV IEC EN 61 000 4 5 between wire and ground 2 kV IEC EN 61 000 4 5 HF wire guided ...

Страница 6: ...7 Auto Start Safety function 2 see page 7 Manual Start Operating mode 5 MANUAL with common button Safety function 1 see page 7 Manual start with common button Safety function 2 see page 7 Manual start with common button Application examples with safety function PRSU M2SI PRSU M2SI ...

Страница 7: ...754 S22 S11 S12 S12 S1 M11124 S21 S22 S11 S12 M10753 Not Aus S21 Fct Safety mat Safety edge Tape switch 4 with cross fault detection SIL 3 PL e Cat 4 Fct Exclusive or contacts 5 with cross fault detection SIL 3 PL e Cat 4 Fct E Stop 6 without cross fault detection SIL 3 PL e Cat 4 1 S21 S22 S11 S12 Schiebeschutztür geschlossen M10752 OSSD1 OSSD2 S22 S21 S11 S12 Sender Empfänger DC 24V 0V M10751 Fc...

Страница 8: ... A 0 6 x 3 5 0 5 Nm 5 LB IN M10248 A A 7 mm 1 x 0 2 2 5 mm2 1 x AWG 24 to 12 2 x 0 2 1 0 mm2 2 x AWG 24 to 18 M10249 A A 7 mm 1 x 0 25 2 5 mm2 1 x AWG 24 to 12 2 x 0 25 1 0 mm2 2 x AWG 24 to 18 M10250 A A 7 mm 1 x 0 2 2 5 mm2 1 x AWG 24 to 12 2 x 0 2 1 5 mm2 2 x AWG 24 to 16 Dimensions dimensions in mm A B PRSU M2SI 110 1 22 5 M4345_a M4345_a 35 115 3 0 0 7 122 6 0 0 7 B A 106 9 Mounting disassemb...

Страница 9: ... variants are available on request The safety relevant data of the complete system has to be determined by the manufacturer of the system Approvals and Markings Demand to our device based on the evaluated neccessary safety level of the application Intervall for cyclic test of the safety function EN ISO 13849 1 PL e with Cat 3 or Cat 4 once per month PL d with Cat 3 once per year IEC EN 62061 IEC E...

Отзывы: