For channels recording flow or rainfall, both daily and monthly total flow is
calculated.
▪
Motor hours with resolution to minutes for each binary channel.
▪
Separate limit alarm for each recording channel.
▪
Separate gradient alarm for each recording channel.
▪
For the duration of an alarm on a channel, you can set a different frequency
of data being written to memory than in normal operation and a different
frequency of data being sent to the server.
▪
Data transmissions are performed under FINET or Modbus RTU protocols.
Data packet transmissions via GSM/GPRS are performed under TCP/IP pro-
tocol.
▪
Regular sending of archived values via GPRS network to the Internet to the
set IP address (to the server with installed MOSTNET-SERVER program).
▪
Phonebook for 10 recipients, up to 3 groups possible.
▪
Alert system based on 14 user configurable and 8 predefined SMS messages.
▪
Activation of sending SMS or transferring data to the server via GPRS
network periodically in time or after reaching the limit value on the measu-
ring channel, after activation of limit or gradient alarm, in case of sensor
fault, low battery voltage, after activation of binary input or on request by
query SMS.
▪
Configurable delay and hysteresis for limit SMS.
▪
25 query and command codes to build a query or control SMS.
▪
Automatic insertion of the instantaneous value of the measuring channel
into the SMS text.
▪
Program-controlled switching on of the modem for a specified time interval
of hours to weeks.
▪
Set the time for sending daily SMS and the time and day for weekly SMS.
▪
Automatic switching between winter and summer time ensures regularity in
sending SMS. Automatic archiving of the current parameter file on the ser-
ver after each parameter change.
▪
The event log contained in the data memory records extraordinary events
(switching on of selected inputs, power failure and power restoration, inco-
ming and outgoing SMS, occurrence of an error signal at connected sensors,
successful and unsuccessful data transfer to the server, etc.).
S t a t i s t i c a l
c a l c u l a t i o n s
A l a r m s
C o m m u n i c a t i o n
O p e r a t i o n a l d i a r y
Содержание H1
Страница 1: ...Small telemetry station for water applications H1 H2 Hydro Logger user manual version 1 10 ...
Страница 2: ...Hydro Logger H1 User manual 2 electronics for ecology FIEDLER ...
Страница 80: ...Hydro Logger H1 User manual 80 electronics for ecology FIEDLER Notes ...
Страница 81: ...Hydro Logger H1 User manual FIEDLER electronics for ecology 81 ...