6.8.2.
Inquiry SMS
The second large group of informative messages consists of replies to incoming
SMS inquiry messages. Depending on what query codes the query SMS contains,
the station compiles the reply text and sends it to the interviewer immediately.
The same rules apply for the composition of the query SMS as for the informa-
tive SMS.
To prevent unauthorized persons from making queries, a password must be inc-
luded at the beginning of the query SMS. This password is accessible to the user
in the "GSM" tab.
A specific query SMS consists of a short message containing only one word
"INFO". This can be written in lower case and must not be preceded by a
PASSWORD. The device responds to the received INFO query with a message
composed according to the codes contained in the control line.
6.8.3.
List of query and control codes
Hydro Logger H1 does not distinguish between upper and lower case
COMMANDS (QUERY CODES CAN BE SEPARATED BY A COMMA
IN THE QUERY SMS)
Bk
The current value of the binary channel
k
(1.. 8).
MHk
Motor hours of the binary channel
k
(1.. 8).
Vk
Current channel value
k
(1.. 17).
Sik
The sum from the installation of the channel
to
(1.. 17).
SDk
The sum from the beginning of the day channel
to
(1.. 17).
SMk
The sum from the beginning of the month channel
to
(1.. 17).
SLk
Sum of the last completed day of the channel
to
(1.. 17).
SKk
Sum of the last completed month of the channel
to
(1.. 17).
SS
Sum of precipitation since the start of the rain (only for the first
precipitation channel).
LVk
Last stored channel value
k
(1-17.
)
Every
The minimum value of today's channel is
k
(1.. 17).
Xk
The maximum value of today's channel
is k
(1.. 17).
Ilk
Minimum value of the previous day's channel
k
(1.. 17).
XLk
Maximum value of the previous day's channel
k
(1.. 17).
PO
Total number of messages sent.
PP
Total number of messages received.
P a s s w o r d :
I N F O q u e r y
Inquiry code
Control
command
Содержание H1
Страница 1: ...Small telemetry station for water applications H1 H2 Hydro Logger user manual version 1 10 ...
Страница 2: ...Hydro Logger H1 User manual 2 electronics for ecology FIEDLER ...
Страница 80: ...Hydro Logger H1 User manual 80 electronics for ecology FIEDLER Notes ...
Страница 81: ...Hydro Logger H1 User manual FIEDLER electronics for ecology 81 ...