66
group 1 file number,
label format group 2
file number, data
length, parity,
minimum output
weight value
d9
= print format: - 0 = Lab 1; 1 = Lab 2; 2 = Lab 3; 3= Lab 4; 4 = Lab 5; 5 = LP-50; 6 = TSC
d10
=label format group 1 file number (00~99): - 00 = file AA00; 1 = file AA01; …98 = file AA98; 99 = file AA99
d11
= label format group 2 file number (00~99): - 00 = file BB00; 1 = file BB01; …98 = file BB98; 99 = file BB99
d12
= data length: - 0 = 7bit; 1 = 8bit
d13
= parity: = 0 = none; 1 = 0dd; 2 = even
d14
: minimum output weight value: - 0 = from 00d; 01 = from 01d; …; 20 = from 20d. Data length = 2 with zero
St
Preset Tare value of
current unit
Data length = 8 including decimal with leading zero.
Sv
Function mode
enable/disable status
d1
= Piece count: - 0 = Off; 1 = On
d2
= ATM: - 0 = Off; 1 = On
d3
= (reserved): - 0 = Off; 1 = On
d4
= Animal Weighing: - 0 = Off; 1 = On
Sw
Machine ID & group
number
d1
= 4-digit machine ID number. Input 4 asterisks (****) to clear machine ID
d2
= 2-digit machine group number. Input 2 asterisks (**) to clear machine ID
Sx
Operator Number
4-digit machine operator number (numeric numbers only). Input 4 asterisks (****) to skip operator number
Sy
Time
24-hour format. Data length = 8. Format = HH:MM:SS
Sz
Date format, date
value
d1
= Date format: - 0 = DDMMYY; 1 = YYMMDD; 2 = MMDDYY
d2
= First 2 digits of d1
d3
= Middle 2 digits of d1
d4
= Last 2 digits of d1
SA
Customer Code
1~18 actual digit of Customer Code set. Blank = Nothing.
SB
Product Code
1~18 actual digit of Product Code set. Blank = Nothing.
Notes: -
Some commands are not legal for trade proposes. Users are assumed to take all responsibilities of using these commands when the instrument is used for trade
application.
System parameter setting commands should always be sent when the instrument is in weighing mode.
After parameter(s) is/are changed, always execute save parameter command (EZ), then