26
6.7.3 When data is accumulated to memory
15
16
17
1.
When a result is accumulated to memory, this instrument displays “
n____x
”.
M+ Indicator
appears to
indicate that memory contains stored data. “x” means the total number of transactions accumulated to
memory.
2.
This instrument returns to normal display status after 2 seconds.
6.7.4 Memory recall and clearance
Accumulation data will be stored in memory and will not be erased by normal power off (by pressing the
[On/Off]
key) process. But changing weight unit or to another working mode will automatically erase accumulation data
stored.
Follow below procedures to recall and clear accumulation data.
1.
Press
[MR/UNIT]
to recall total accumulated weight.
2.
Instrument flashes between “A____Y” (Y means the number of transactions accumulated) and total
accumulated result.
3.
At this point: -
•
Press
[ZERO]
to quit, or
•
Press
[CE/x10]
to clear memory. After
[CE/x10]
is pressed, instrument display Clear and M+
Indicator disappears to indicate all no data is stored in memory.
6.8 Extended Display Mode
18
When F68 is set to OIML or NTEP, by pressing
[CE/x10],
the weighing resolution will be temporary (for 5
seconds) changed to 10 times finer. Display keeps flashing when instrument is displaying the extended result.
6.9. Auto Power Off, Display Brightness
6.9.1 When powered by external power adaptor
Both auto power off function and auto power saving function will be automatically disabled.
6.9.2 When instrument is powered by rechargeable battery
When F31 is set to on, indications brightness will turn to minimum when weight remains stable / unchanged for
30 second.
6.10 Customer & Product Code
This instrument supports customer & product code. Once entered, these will be printed and output through the
assigned comport. Maximum data Length as below: -
•
Customer Code = 18 digit.
•
Product Code = 18 digit.
Refer to markings on the numeric keys of instrument keyboard for number, letters and symbols assigned to
each key.
15
Memory Accumulation Function accumulated weight results only.
16
When F16 and F17 is set to mode Auto1~3, unstable result or result which is less than 20d (or 20d
1
for dual weighing range/interval
mode) will not be accumulated to memory.
17
All data stored will be erased when weight unit or working mode is changed.
18
When F68 = OIML or NTEP.