69
Ar
Comport 1 working
mode,
baud
rate,
output protocol, print
stability
control,
transmission interval,
Auto
Accumulation,
number of copy, check
result control, print
format, label format
group 1 file number,
label format group 2 file
number, data length,
parity, minimum output
weight value
d1
= working mode: - 0 = Auto 1; 1 = Auto 2; 2 = Auto 3; 3 = Manual; 4 = PC; 5 = Scanner; 6 = Off
d2
baud rate: - 0 = 1200; 1 = 2400; 2 = 4800; 3 = 9600; 4 = 19200; 5 = 38400; 6 = 57600; 7 = 115200; 8 = 256000
d3
= protocol: - 0 = Protocol 1; 1 = Protocol 2; … ; 8 = Protocol 9
d4
= print stability control: - 0 = no (disable); 1 = Yes (enable)
d5
= transmission interval: - 0 = int 0; 1 = int 0.5; 2 = int 1.0; 3 = int 1.5; …..; 9 = int 300.
d6
= Auto Accumulation: - 0 = Off (disable); 1 = On (enable)
d7
= number of copy: - 0 = 1 copy; … 7 = 8 Copy
d8
= check result control: - 0 = no (disable); 1 = Yes (enable)
d9
= print format: - 0 = Lab 1; 1 = Lab 2; 2 = Lab 3; 3= Lab 4; 4 = Lab 5; 5 = LP-50; 6 = TSC
d10
=label format group 1 file number (00~99): - 00 = file AA00; 1 = file AA01; …98 = file AA98; 99 = file AA99
d11
= label format group 2 file number (00~99): - 00 = file BB00; 1 = file BB01; …98 = file BB98; 99 = file BB99
d12
= data length:- 0 = 7bit; 1 = 8bit
d13
= parity: = 0 = none; 1 = 0dd; 2 = even
d14
: minimum output weight value: - 0 = from 00d; 01 = from 01d; … ; 20 = from 20d. Data length = 2 with leading
zero
As
Comport 2 working
mode,
baud
rate,
output protocol, print
stability
control,
transmission interval,
Auto
Accumulation,
number of copy, check
result control, print
format, label format
group 1 file number,
label format group 2 file
number, data length,
parity, minimum output
weight value
d1
= working mode: - 0 = Auto 1; 1 = Auto 2; 2 = Auto 3; 3 = Manual; 4 = PC; 5 = CMD; 6 = Off
d2
baud rate: - 0 = 1200; 1 = 2400; 2 = 4800; 3 = 9600; 4 = 19200; 5 = 38400; 6 = 57600; 7 = 115200; 8 = 256000
d3
= protocol: - 0 = Protocol 1; 1 = Protocol 2; … ; 8 = Protocol 9
d4
= print stability control: - 0 = no (disable); 1 = Yes (enable)
d5
= transmission interval: - 0 = int 0; 1 = int 0.5; 2 = int 1.0; 3 = int 1.5; …..; 9 = int 300.
d6
= Auto Accumulation: - 0 = Off (disable); 1 = On (enable)
d7
= number of copy: - 0 = 1 copy; … 7 = 8 Copy
d8
= check result control: - 0 = no (disable); 1 = Yes (enable)
d9
= print format: - 0 = Lab 1; 1 = Lab 2; 2 = Lab 3; 3= Lab 4; 4 = Lab 5; 5 = LP-50; 6 = TSC
d10
=label format group 1 file number (00~99): - 00 = file AA00; 1 = file AA01; …98 = file AA98; 99 = file AA99
d11
= label format group 2 file number (00~99): - 00 = file BB00; 1 = file BB01; …98 = file BB98; 99 = file BB99
d12
= data length:- 0 = 7bit; 1 = 8bit
d13
= parity: = 0 = none; 1 = 0dd; 2 = even
d14
: minimum output weight value: - 0 = from 00d; 01 = from 01d; … ; 20 = from 20d. Data length = 2 with leading
zero
At
Current weight unit and
function mode
d1
= weight unit: - 0 = kg; 1 = g; 2 = lb
d2
= function mode: - 0 = weighing; 1 = piece count; 2 = AT 1; 3 = (reserved); 4= animal weighing
Av
Auxiliary
Function
mode
enable/disable
status
d1
= Piece count: - 0 = Off; 1 = On
d2
= ATM: - 0 = Off; 1 = On
d3
= (reserved): - 0 = Off; 1 = On
d4
= Animal Weighing: - 0 = Off; 1 = On