23
6. Basic Operations
6.1 Power On, Inputting Operator Number & Power Off
To power on press and hold
[On/Off]
for 0.5 second.
To power off press and hold
[On/Off]
.
After powered on, instrument will display: -
1.
Software number.
2.
Software revision.
3.
All display segments.
4.
Calibration count value.
5.
Parameter set count value.
6.
Battery voltage.
7.
Capacity & division set (in the format of Max plus 1 division).
8.
At this point, depends on internal function number F28 setting, instrument may ask for operator number
input. If this is the case: -
•
Input 4-digit operator number, or
•
Press
[CE/x10]
then
[PRINT/M+]
to skip operator number when oP appears.
9.
At this point, instrument is in weighing mode and is ready for operation.
6.2 Warm Up Time & set Weight to Zero when Unloaded
It is important to allow the instrument enough warm up time. This is especially important when this instrument
is running at high resolution (e.g. 6000d or higher) application. Refer to
1.3
for details.
If zero result is not obtained when unloaded, press
[ZERO]
to set weight displayed to zero.
6.3 Keyboard Lock
When keyboard lock is enabled, only
[On/Off]
,
[ZERO] and [TARE]
key can function. Refer to F20 on
5.4
for
keyboard lock settings.
6.4 Tare Modes
Tare function is used to cancel the weight of a box or a container in order to get the net weight result. Various
tare modes are available. Refer to below paragraphs for details.
6.4.1 Manual tare
5
1.
Remove all loads from platform.
2.
Make sure that the
Zero Indicator
is on. If not, press
[ZERO]
.
3.
Place container on platform.
4.
Press
[TARE]
.
5.
Weight displayed will become zero and
Net Indicator
appears to indicator tare is in effect and weight
being displayed is net weight.
6.
To cancel tare effect, remove all loads from platform and press
[TARE]
.
7.
Net Indicator
disappears.
5
Maximum tare (subtractive) = -Max for single range mode and dual weighing range/interval mode.