Table 4-65: ECE Configuration Parameters
UNI Ports
The list of User Network Interfaces for the ECE
Ingress Matching
Tag Type
The tag type for the ECE. The possible values are:
Any
: The ECE will match both tagged and untagged frames
.
Untagged
: The ECE will match untagged frames only
.
C-Tagged
: The ECE will match custom tagged frames only.
S-Tagged
: The ECE will match service tagged frames only
.
Tagged
: The ECE will match tagged frames only.
Frame type
The frame type for the ECE. The possible values are:
Any
: The ECE will match any frame type.
IPv4
: The ECE will match IPv4 frames on
ly.
IPv6
: The ECE will match IPv6 frames only.
Actions
Direction
The EVCs and ECEs are used to setup flows in one or both directions
as determined by the ECE Direction parameter. If the ECE is
bidirectional, the ingress rules of the NNI ports will be setup to match
the traffic being forwarded to NNI ports. The possible values are:
Both
: Bidirectional.
UNI-to-NNI
: Unidirectional from UNI to NNI
.
NNI-to- UNI
Unidirectional from NNI to UNI
EVC ID Filter
The EVC ID for the ECE. The ECE is only active when mapping to an
existing EVC. The possible values are:
Any
: No EVC ID filter is specified. (EVC ID filter status is "don't-care".)
EVC ID Value
When "Specific" is selected for the VLAN ID filter, you can enter a
specific value.
The allowed value is from 1 through 256
Tag Pop Count
The ingress tag pop count for the ECE The allowed range is from
0
through
2
..
Policy ID
The ACL Policy ID for the ECE for matching ACL rules
is an acronym for
A
ccess
C
ontrol
L
containing access control entries that specify individual users or
groups permitted or denied to specific traffic objects, such as a
process or a program.
Class
The traffic class for the ECE.
The allowed range is from
0
through
7
or
disabled
.
MAC Parameters
SMAC Filter
The source MAC address for matching the ECE. The possible values are:
Any
: No SMAC filter is specified. (SMAC filter status is "don't-care".)
Specific
: If you want to filter a specific SMAC value with this ECE, choose this
value. A field for entering a specific value appears.
Содержание Falcon Gen-3 M-Class
Страница 1: ...Falcon Gen 3 M Class User Guide nFalcon M Falcon MX Falcon MX Software version 7 4 0 www fibrolan com...
Страница 16: ...Falcon M Class User Guide 16 2 System Description 2 1 Block Diagram Figure 1 7 M Class functional block diagram...
Страница 90: ...Falcon M Class User Guide 90...
Страница 107: ...Falcon M Class User Guide 107 Figure 4 57 DSCP Translation...
Страница 139: ...Falcon M Class User Guide 139...
Страница 187: ...Falcon M Class User Guide 187 Figure 4 99 RADIUS Statistics for Server...
Страница 197: ...Falcon M Class User Guide 197 4 11 6 SyncCenter Status Figure 4 104 Sync Center Status...
Страница 214: ...Falcon M Class User Guide 214...
Страница 227: ...Falcon M Class User Guide 227...
Страница 234: ...Falcon M Class User Guide 234...
Страница 328: ...Falcon M Class User Guide 328 Figure 4 189 Connectivity check to a MIP and MEP using Loopback function...
Страница 358: ...Falcon M Class User Guide 358 Figure 4 216 sFlow Configuration displays...
Страница 376: ...Falcon M Class User Guide 376...
Страница 403: ...Falcon M Class User Guide 403...