Table 4-62:
EVC Control List Configuration
Parameters
EVC ID
The EVC ID identifies the EVC. The range is from
1
through
128
.
VID
The VLAN ID in the PB network. It may be inserted in a C-tag, S-tag or
S-custom tag depending on the NNI port VLAN configuration. The range
is from
1
through
4095
.
IVID
The Internal/classified VLAN ID in the PB network. The range is from
1
through
4095
.
Learning
The learning mode for the EVC controls whether source MAC addresses
are learned for frames matching the EVC. Learning may be disabled if
the EVC only includes two UNI/NNI ports. The possible values are:
Enabled
: Learning is enabled (MAC addresses are learned).
Disabled
: Learning is disabled (MAC addresses are not learned).
Inner Tag Type
The inner tag type is used to determine whether an inner tag is inserted
in frames forwarded to NNI ports. The possible values are:
None
: An inner tag is not inserted.
C-tag
: An inner C-tag is inserted.
S-tag
: An inner S-tag is inserted.
S-custom-tag
: An inner tag is inserted and the tag type is determined
by the VLAN port configuration of the NNI
Inner VID Mode
The inner VID Mode affects the VID in the inner and outer tag. The
possible values are:
Normal
: The VID of the two outer tags aren't swapped.
Tunnel
: The VID of the two outer tags are swapped, so that the VID of
the outer tag is taken from the Inner Tag configuration and the VID of
the inner tag is the EVC VID. In this mode, the NNI ports are normally
configured to do EVC classification based on the inner tag.
Inner Tag VID
The Inner tag VLAN ID. The allowed range is from
0
through
4095
.
Inner Tag
PCP/DEI
Preservation
The inner tag PCP and DEI preservation. The possible values are:
Preserved
: The inner tag PCP and DEI is preserved.
Fixed
: The inner tag PCP and DEI is fixed.
Inner Tag PCP
The inner tag PCP value. The allowed range is from
0
through
7
.
Inner Tag DEI
The inner tag DEI value. The allowed value is
0
or 1
Outer Tag VID
The EVC outer tag VID for UNI ports. The allowed range is from
0
through
4095
NNI Ports
The list of Network to Network Interfaces for the EVC.
Modification
Button
You can modify each EVC in the table using the following button
: Adds new EVC.
Buttons
Refresh:
Click to refresh the displayed table starting from the “Start from the MAC
address” and “VLAN” input fields.
Auto-refresh
: Check this box to refresh the page automatically.
Automatic refresh occurs every 3 seconds.
Remove All
: Click to remove all ECEs.
By clicking on the right lowest plus sign on the previous display
EVC Control List
Configuration,
you get the EVC Configuration displays. Refer to the next section
Содержание Falcon Gen-3 M-Class
Страница 1: ...Falcon Gen 3 M Class User Guide nFalcon M Falcon MX Falcon MX Software version 7 4 0 www fibrolan com...
Страница 16: ...Falcon M Class User Guide 16 2 System Description 2 1 Block Diagram Figure 1 7 M Class functional block diagram...
Страница 90: ...Falcon M Class User Guide 90...
Страница 107: ...Falcon M Class User Guide 107 Figure 4 57 DSCP Translation...
Страница 139: ...Falcon M Class User Guide 139...
Страница 187: ...Falcon M Class User Guide 187 Figure 4 99 RADIUS Statistics for Server...
Страница 197: ...Falcon M Class User Guide 197 4 11 6 SyncCenter Status Figure 4 104 Sync Center Status...
Страница 214: ...Falcon M Class User Guide 214...
Страница 227: ...Falcon M Class User Guide 227...
Страница 234: ...Falcon M Class User Guide 234...
Страница 328: ...Falcon M Class User Guide 328 Figure 4 189 Connectivity check to a MIP and MEP using Loopback function...
Страница 358: ...Falcon M Class User Guide 358 Figure 4 216 sFlow Configuration displays...
Страница 376: ...Falcon M Class User Guide 376...
Страница 403: ...Falcon M Class User Guide 403...