ADVAnCED PARAMETERS
35. Auto-calibration after power on
This parameter determines the trigger of auto-calibration procedure,
e.g. power on, load error, etc.
Available settings:
0
- no auto-calibration of the load after power on
1
- Auto-calibration performed after first power
on
2
- Auto-calibration performed after each power
on
3
- Auto-calibration performed after first power
on or after each LOAD ERROR alarm (no load,
load failure, burnt out bulb), if parameter 37 is
set to 1 also after alarms: SURGE (Dimmer 2 out-
put overvoltage) and OVERCURREnT (Dimmer
2 output overcurrent)
4
- Auto-calibration performed after each pow-
er on or after each LOAD ERROR alarm (no load,
load failure, burnt out bulb), if parameter 37 is
set to 1 also after alarms: SURGE (Dimmer 2 out-
put overvoltage) and OVERCURREnT (Dimmer
2 output overcurrent)
Default setting:
1
Parameter size:
1
[byte]
37. Behaviour of the Dimmer 2 after OVERCURRENT or SURGE
Occuring of errors related to surge or overcurrent results in turning
off the output to prevent possible malfunction. By default the device
performs three attempts to turn on the load (useful in case of mo-
mentary, short failures of the power supply).
Available settings:
0
- device permanently disabled until re-en-
abling by command or external switch
1
- three attempts to turn on the load
Default setting:
1
Parameter size:
1
[byte]
39. Power limit - OVERLOAD
Reaching the defined value will result in turning off the load. Addi-
tional apparent power limit of 350VA is active by default.
Available settings:
0
- functionality disabled
1-350
- 1-350W
Default setting:
250
Parameter size:
2
[bytes]
NOTE
Parameter 39 is rele-
vant only when pa-
rameter 58 is set to 0.
i