ADDITIOnAL FUnCTIOnALITY
#12: Additional functionality
Software update
Dimmer 2 features remote software update (initiated by the main
controller). Update status is signalled by the LED indicator with cyan
colour:
• slow blinking
- transferring data via Z-Wave and saving to the
flash memory
• fast blinking
- copying data from the external memory to the
memory of the microcontroller
Operating alarm data frames
FIBARO System allows user to set response of devices to alarm situa-
tions (response to data-frames ALARM_REPORT and SEnSOR_ALARM_
REPORT). Dimmer 2 responds to the following types of alarms:
• General Purpose Alarm - GEnERAL PURPOSE ALARM
• Smoke Alarm - ALARM CO2, ALARM CO, ALARM SMOKE
• Water Flooding Alarm - ALARM WATER
• Temperature Alarm - ALARM HEAT
Alarm data-frames are sent by devices that are system sensors (e.g.,
flood sensors, smoke detectors, motion detectors, etc.).
The device may respond in the following manner to received da-
ta-frames (settings are configured in configuration parameters, see
„Advanced parameters” on page 22):
0 -
DEACTIVATION
- the device does not respond to alarm data frames
1 -
DIMMER 2 ON
- the device turns on after detecting an alarm
2 -
DIMMER 2 OFF
- the device turns off after detecting an alarm
3 -
ALARM FLASHING
- the device periodically changes its status to
the opposite when it detects an alarm (lights on/off alternately)