30
ADVAnCED PARAMETERS
NOTE
Alarm state may be
cancelled earlier, as
a result of pressing
the switch or sending
the Z-Wave command
frame.
i
GROUP 40 - Dimmer 2 operation - Alarms
40. Response to General Purpose Alarm
Available settings:
0
- no reaction
1
- Turn on the load
2
- Turn off the load
3
- Load blinking
Default setting:
3
Parameter size:
1
[byte]
41. Response to Water Flooding Alarm
Available settings:
0
- no reaction
1
- Turn on the load
2
- Turn off the load
3
- Load blinking
Default setting:
2
Parameter size:
1
[byte]
42. Response to Smoke, CO or CO2 Alarm
Available settings:
0
- no reaction
1
- Turn on the load
2
- Turn off the load
3
- Load blinking
Default setting:
3
Parameter size:
1
[byte]
43. Response to Temperature Alarm
Available settings:
0
- no reaction
1
- Turn on the load
2
- Turn off the load
3
- Load blinking
Default setting:
1
Parameter size:
1
[byte]
44. Time of alarm state
Available settings:
1-32767
(1-32767 seconds)
Default setting:
600
(600s)
Parameter size:
2
[bytes]
Alarm settings - reports
45. OVERLOAD alarm report
(load power consumption too high)
Available settings:
0
- no reaction
1
- Send an alarm frame
Default setting:
1
Parameter size:
1
[byte]