27
ADVAnCED PARAMETERS
Available settings:
0
- all groups (II-V) sent as non-secure
1
- 2nd group sent as secure
2
- 3rd group sent as secure
4
- 4th group sent as secure
8
- 5th group sent as secure
15
- all groups (II-V) sent as secure
Default setting:
15
Parameter size:
1
[byte]
28.
Scene activation functionality
SCEnE ID depends on the switch type configurations.
Available settings:
0
- functionality deactivated
1
- functionality activated
Default setting:
0
Parameter size:
1
[byte]
SCENE ID value sent at specified configuration:
Momentary switches
SCEnE ID: S1 input
SCEnE ID: S2 input
16 : 1 x click
14 : 2 x click
- : 3 x click
12 : hold
13 : release
26 : 1 x click
24 : 2 x click
25 : 3 x click
22 : hold
23 : release
Toggle switches
SCEnE ID: S1 input
SCEnE ID: S2 input
10 : OFF to On
11 : On to OFF
14 : 2 x click
- : 3 x click
20 : OFF to On
21 : On to OFF
24 : 2 x click
25 : 3 x click
Roller blinds switches
SCEnE ID: S1 input
SCEnE ID: S2 input
10 : turn On (1 x click)
13 : release
14 : 2 x click
- : 3 x click
17 : brightening
11 : turn OFF (1 x click)
13 : release
14 : 2 x click
15 : 3 x click
18 : dimming
29. Switch functionality of S1 and S2
This parameter allows for switching the role of keys connected to S1
and S2 without changes in connection.
Available settings:
0
- standard mode
1
- S1 operates as S2, S2 operates as S1
Default setting:
0
Parameter size:
1
[byte]
NOTE
Enabling scene activa-
tion functionality may
cause slight delay in
response to external
switches and sending
associations.
i
NOTE
Parameter 27 values
may be combined,
e.g. 1+2=3 means that
2nd & 3rd group are
sent as secure.
i