Equipment Details
97
Control Panel Diagnostics
Refrigerators with a LCD control panel have
a special diagnostics area which displays an
error code if there is a fault.
•
Fault 1:
AC heater current is measured to
be 75% below nominal current.
Action: Contact your dealer or a Thetford
Service Centre.
•
Fault 2:
DC heater current is measured to
be 75% below nominal current.
Action: Contact your dealer or a Thetford
Service Centre.
•
Fault 3:
AC heater is ON when it should
be OFF.
Action: Contact your dealer or a Thetford
Service Centre.
•
Fault 4:
DC heater is ON when it should
be OFF.
Action: Contact your dealer or a Thetford
Service Centre.
•
Fault 5:
Senses flame when gas should
be OFF.
Action: Contact your dealer or a Thetford
Service Centre.
•
Fault 6:
Senses gas output terminal ON
when should be OFF.
Action: Contact your dealer or a Thetford
Service Centre.
•
Fault 7:
Senses gas output terminal OFF
when should be ON.
Action: Contact your dealer or a Thetford
Service Centre.
•
Fault 8:
AC mains supply is 20% below
nominal.
Action: Your controls are in manual AC
mode, but there is no power available.
Check if you plugged in the 230V
connection, if so the voltage supply on
the 230V connection is to low, contact
the power supplier.
•
Fault 9:
Gas lockout because flame fails
to ignite after 30 seconds.
Action: Your controls are in manual gas
mode, but the flame fails to ignite. Check
if your gas cylinder is empty or if one of
the shut-off valves is closed. Select
another energy source. Reset the fridge 3
or 4 times in gas-mode until flame ignites.
Contact your dealer or a Thetford Service
Centre if problem isn't resolved.
•
Fault 10:
No "engine running" signal is
present and control is in Manual DC
mode.
Action: Your controls are in manual DC
mode and the engine of your vehicle is
not running. The refrigerator can only cool
on 12V when the engine of your vehicle is
running. Start the engine or select a
different energy mode.
•
Fault 11:
No energy source is available
and control is in AUTO mode.
Action: Your controls are in AUTO mode,
but no energy source is available. Start
the engine, connect the 230V supply or
open the gas supply and reset the
refrigerator by turning it of and on again.
•
Fault 12:
Contact your dealer or a
Thetford Service Centre.
•
Fault 13:
Thermistor fails; control
automatically switches to Backup mode
(BOS).
Action: Check if the connector above the
fin on the inside of the cabinet is correctly
plugged in. If so contact your dealer or a
Thetford Service Centre.
•
Fault 14:
Display Board and Power board
lost communication with each other.
Action: Contact your dealer or a Thetford
Service Centre.
Содержание X2-50 Cab
Страница 8: ...THE MOTORHOME CODE Code of Conduct 12 The Country Code 14 The Coastal Code 14 ...
Страница 19: ... EN ROUTE Spare Wheel Removal 24 ...
Страница 21: ...ARRIVAL AT SITE Positioning the Motorhome 30 ...
Страница 27: ...Connecting Services 35 Typical gas schematic drawing ...
Страница 119: ...SAFETY SECURITY Fire 26 Ventilation 26 Escape Paths 26 Children 26 Security 26 ...