Equipment Details
82
Failure : The refrigerator does not work on 230V
Possible cause
Action you can take
On-board fuse defective.
Fit new fuse.
No connection to supply voltage.
Establish power connection.
AES: gas operation despite connection
Appliance switches to gas operation due to
to the supply voltage?
insufficient supply voltage (automatically
switches back to 230 V operation)
Failure : The refrigerator does not cool sufficiently
Possible cause
Action you can take
Inadequate ventilation to the unit.
Check that the ventilation grilles are not
covered.
The thermostat setting is too low.
Turn the thermostat to a higher setting.
There is too much ice on the condenser.
Check that the refrigerator door seals when
shut.
Too much warm food put inside.
Let food cool down first.
Appliance running for a short time.
Wait several hours, check again.
MAINTENANCE
• Works on gas components and electrical
installation may only be carried out by
authorised personnel. We recommend to
contact your Dometic Service Centre.
• EN 1949 stipulates that the appliance´s
gas equipment and its associated fume
system must be inspected after
installation and a certificate issued.
Afterwards a qualified technician must
inspect according to EN 1949 every two
years and a certificate issued.
It is the user’s responsibility to arrange for
inspections after purchase.
• It is recommended that the gas burner be
inspected and cleaned as necessary at
least once a year. We recommend
maintenance following an extended
shutdown of the vehicle.
PRODUCT LIABILITY
Product liability of Dometic GmbH does not
include damages which may arise from faulty
operation, improper alterations or intervention
in the equipment, adverse effects from the
environment such as changes in temperature
and air humidity, which may impact the
equipment itself or the direct vicinity of the
equipment or persons in the area.
Содержание X2-50 Cab
Страница 8: ...THE MOTORHOME CODE Code of Conduct 12 The Country Code 14 The Coastal Code 14 ...
Страница 19: ... EN ROUTE Spare Wheel Removal 24 ...
Страница 21: ...ARRIVAL AT SITE Positioning the Motorhome 30 ...
Страница 27: ...Connecting Services 35 Typical gas schematic drawing ...
Страница 119: ...SAFETY SECURITY Fire 26 Ventilation 26 Escape Paths 26 Children 26 Security 26 ...