36
Festo — VTSA-F-CB — 2021-06a
Product overview
4.2.1.1
Pressure supply to the valve terminal
The valve terminal can be supplied with operating pressure by the following components:
–
Pneumatic supply plate
–
Right end plate
–
Soft start valve
The following components can be used for additional power supplies:
–
Pneumatic supply plates
–
Vertical supply plates
4.2.1.2
Pilot air supply
The pilot air can be supplied to the following components:
Characteristic
Internal pilot air supply
External pilot air supply
Type of pilot air supply
Pilot air is branched internally
from port (1).
Pilot air is supplied externally.
Supply component for the first/
right pressure zone
–
Right-hand end plate
VABE-…R-...
–
Soft start valve
VABF-…-P5A4S1…
–
Pilot air switching valve
VSVA-BT-M32CS1-…
–
Right end plate VABE-…RZ-...:
feed at port (14)
–
Pilot air switching valve
VSVA-BT-M32CS2-…: supply
at port (2) of the manifold
sub-base
Supply component for the other
pressure zones
–
Soft start valve
VABF-…-P5A4S1…
–
Pilot air switching valve
VSVA-BT-M32CS1-…
–
Pilot air switching valve
VSVA-BT-M32CS2-…: supply
at port (2) of the manifold
sub-base
Required pilot pressure
–
Diagrams of the dependency
between working pressure and
pilot pressure
Working pressure at port (1)
3 … 10 bar
–0.9 … +10 bar, depending on
the valves in use
Vacuum or low-pressure opera-
tion
Not possible
Possible
Tab. 23: Types of pilot air supply
Functional failure or malfunctions due to faulty pilot air supply
• Supply every pressure zone with working pressure and pilot pressure. Do not form pressure-free
zones
4.2.1.4 Forming pressure zones.
• Use only one supply component for the pilot air supply in every pressure zone.
• Required pilot pressure at port (12/14)