Festo — VTSA-F-CB — 2021-06a
Installation
51
Assembly
Wall
Mounting system H-rail
CPX modules (metal) and VTSA-,
VTSA-F- and VTSA-F-CB modules
(18 … 52 mm)
x
x
Check mounting
conditions
Tab. 34: Mounting types
Mounting conditions and dynamic load
è
Mounting instructions CPX-VTSA.
6.2
Mounting the labelling elements
Optional identification holders can be mounted on the valves to identify pressure zones and voltage
zones. The identification holder provides space for 1 IBS-6X10 inscription label and 2 ASCF-T-Sx
labels.
1
2
Fig. 29: Mounting the identification holder
1
Identification holder
2
Mounting on the valve
•
Press the identification holder into the holder on the valve and snap it into place.
Disassembly
•
Pull the identification holder out of the holder on the valve.
7
Installation
7.1
Installation Pneumatics
7.1.1
Compressed air preparation
7.1.1.1
Operation with unlubricated compressed air
Unfiltered compressed air will reduce the service life of the valve terminal.
An excess of residual oil content in the compressed air will cause valves to malfunction, and will cause
the life-time lubrication necessary for unlubricated operation to be washed out.
•
Maintain the residual oil content
–
Organic oils (oils based on synthetic or native esters, e.g. rapeseed oil methyl ester): maximum
residual oil content 0.1 mg/m3 ISO 8573-1:2010 [–:–:2]
–
Mineral oils (e.g. HLP oils to DIN 51524 Parts 1 to 3) or oils based on polyalphaolefins (PAO):
maximum residual oil content 5 mg/m3 ISO 8573-1:2010 [–:–:4]