Technical data
12.1
Ambient conditions
The valves can be operated up to a temperature of –5 °C. At low temperatures, condensate and
moisture can freeze.
Recommendation:
• To remove condensate and moisture, install a dryer.
Ambient conditions
Permitted temperature ranges
–
Storage
[°C]
–20 … +60
–
Operation
[°C]
–5 … +50
–
Medium
[°C]
–5 … +50
Relative humidity
[%]
0 … 90
Degree of protection
IP65 (with cable from the accessories of Festo)
Corrosion protection
Corrosion resistance class CRC 0
Mounting position
Any for wall mounting and support system
mounting
Resistance to vibration/shock resistance
See assembly instructions for terminal CPX/
valve terminal VTSA
Tab. 57: Technical data: ambient conditions
12.2
Technical data, mechanical
Weight
Width
18 mm
26 mm
42 mm
52 mm
Left-hand end plate (CPX terminal)
[g]
Approx. 80
Complete CPX module
[g]
Approx. 210
Pneumatic interface
[g]
1470
Supply plate with exhaust plate
[g]
600
Supply plate with exhaust air cover
[g]
611
Soft start valve with manifold sub-base
[g]
1200
Right end plate (axial ports)
[g]
339
Manifold sub-base
1)
[g]
447
634
340
591
Valve
[g]
Approx.
180
Approx.
320
Approx.
450
Approx.
726