Festo — VTSA-F-CB — 2021-06a
Parameterisation
67
8.1.2
Completing commissioning of the pneumatic components
8.1.2.1
Cover cap for manual override (optional)
It takes additional force to remove the cover caps. The snap hooks of the cover caps can be damaged
during disassembly.
• Mount the cover caps only after commissioning.
Mounting cover cap
1
2
3
Fig. 40: Mounting the cover cap
1
Cover cap for MO, non-detenting/robust
2
Cover cap for MO, concealed
3
Cover cap for MO, non-detenting
Prerequisite: the MO is in normal position.
•
Align the cover cap and clip the snap hooks into the recesses of the MO.
Ä
The cover cap is mounted.
Demounting cover cap
•
Use a suitable screwdriver to lever the cover cap for the MO off the MO.
8.2
Safe output module CPX-FVDA-P2
Commissioning
è
Description CPX-FVDA-P2.
9
Parameterisation
9.1
Process data
Process data of the soft start valves
The process data belong to the following type codes:
–
VABF-S6-1-P5A4S2YE-G12-1T5-PA
–
VABF-S6-1-P5A4S1YE-G12-1T5-PA
–
VABF-S6-1-P5A4S2S-G12-1T5-PA
–
VABF-S6-1-P5A4S1S-G12-1T5-PA