Commissioning
© Festo Didactic • MPS
®
PA Compact Workstation
55
Interfaces Touch panel
Please connect the DH485 port of the communication module to 1761-NET-AIC.
3
1
2
Panel View 600+ - back view
1
PanelView Plus 600
2
DH 485 port for communication to PLC on additional communication module
3
Base configuration unit with Ethernet port for communication to PLC (Compact
Logix)
•
Observe technical data!
•
Connect the compressed air supply to the service unit.
•
Set the service unit at 6 bar (600 kPa).
•
The stations are supplied with 24 V DC voltage (max. 5 A) via a power supply
unit. Connect the 230 VAC shock proof plug of the power supply with the main
cable to the main power supply.
•
The voltage supply of the complete station is provided via the PLC or controller.
•
Heating element: Connect the 230 VAC shock proof plug of the power supply with
the main cable to the fast circuit breakter with main power supply.
5.4
Pneumatic connection
5.5
Voltage supply