Design and function
22
© Festo Didactic • MPS
®
PA Compact Workstation
The increasing fluid level into the upper tank B102 is monitored at a certain
minimum level by float switch S112 (1). If the mounting position is changed the
switch can also indicate the decreasing level.
1
Level monitoring with float switch for threshold function S112
The binary 24 V input signals (nc) is connected to the I/O-terminal XMA1. The cable
of the switch has a plug connection for easy connect/disconnect on changing the
mounting position.
Threshold function