Commissioning
© Festo Didactic • MPS
®
PA Compact Workstation
41
The MPS
®
PA Cmpact Workstation can be controlled in different ways. In the
following steps, the different conroll variants will be described.
5.3.1
Simulation box digital/analog and MPS
®
PA Compact Workstation
All cable connections are described for a MPS
®
PA Compact Workstation with
Simulationbox.
•
Simulation box D/A– station: connect the Syslink plug of the simbox with the
XMA1 socket of the I/O terminal (2) of the station with a SysLink cable (3).
•
Simulation box D/A– station: connect the analog plug of the simbox with the X2
socket of the analog terminal (4) of the station with analog cable (5).
•
Simulation box D/A– power supply unit: connect 4 mm safety plugs (red and
blue) of the simbox and power supply unit with 4 mm safety plugs
cable (red = + / blue = — ).
By using the crossover analoge cable with the simulation box only the first two
analog cannels (0 = Level; 1 = Flow) can be displayed.
5.3
Cable connections
Notice